Določevanje kroma(VI) v mikrofluidnem sistemu z optotermično mikroskopsko detekcijo
Krom (Cr) spada med kovinske onesnaževalce, katerega učinek na okolje je močno odvisen od oksidacijskega stanja. Za ljudi je problematična njegova šestvalentna oblika Cr(VI), ki je rakotvorna, zato je potreba po hitri detekciji Cr(VI) velika. V diplomski nalogi smo preverjali točnost detekcije Cr(VI) ob prisotnosti različnih presežkov motečih elementov kot so šestvalentni molibden (Mo(VI)), petvalentni vanadij (V(V)), trivalentno železo (Fe(III)) in dvovalentno živo srebro (Hg(II)). Po kolorimetrični reakciji čistega standarda Cr(VI) in raztopin motečih elementov z difenilkarbazidom (DPC) smo za meritev uporabili spektrofotometrijsko metodo (SPEC) in mikroskopijo s toplotnimi lečami v mikrofluidnem sistemu za pretočno injekcijsko analizo (µFIA - TLM). Rezultati so pokazali, da največjo napako pri meritvah povzroči prisotnost V(V). Izvedli smo tudi študijo razpada preiskovanih kompleksov Cr-DPCO, Mo-DPCO, V-DPCO, Fe-DPCO in Hg-DPCO v odvisnosti od moči vzbujevalnega laserja v mikrofluidnem TLS sistemu (TLM). Dokazali smo, da je železov kompleks stabilnejši od ostalih preiskovanih ionskih kompleksov, ki so znani kot fotolabilni. Z izračunom spodnje meje določevanja (LOD) za SPEC in TLM metodo smo pokazali, da je TLM, zaradi nižje LOD vrednosti primernejša metoda za detekcijo nizkih koncentracij Cr(VI) v vzorcu. Analiza vzorcev iz Soče in Ljubljanice je prikazala sliko realnega stanja v, potencialno s Cr(VI), onesnaženi reki.
Chromium is one of metal pollutants, whose effect on the environment strongly depends on its oxidation state. Its most harmfull state for people is hexavalent state Cr(VI) which is carcinogenic. In our study we were checking its determination at presence of different concentration of interfering ions V(V), Mo(VI), Fe(III) and Hg(II). After colorimetric reaction of standard Cr(VI) and other interference elements with diphenylcarbazide (DPC) we measured samples with spectrophotometric method (SPEC) and thermal lens microscopy in microfluidic flow-injection system (μFIA - TLM). The highest influences on detection of Cr(VI) were measured in presence of V(V). We also studied degradation of Cr-DPCO, Mo-DPCO, V-DPCO, Fe-DPCO and Hg-DPCO in dependence of input laser power in TLM system. We proved that Fe-DPCO complex is more stable than other reasurched ion complexes, all known as fotolable. The calculated limit of detection (LOD) for SPEC and microfluid TLS (TLM) shows, that TLM is more appropriate method for detection of lower Cr(VI) concentration in samples. Analysis of real water samples from Soča and Ljubljanica rivers show the real state of rivers, which potentially could be polluted by Cr(VI).
2015
2015-09-26 09:47:47
1060
spektrofotometrija, TLS, TLM, fotolabilnost, moteči elementi
spectrophotometry, TLS, TLM, photolable, interference elements
mb11
Mladen
Franko
991
Sara
Malovrh
70
COBISS_ID
3
4046075
NUK URN
18
URN:SI:UNG:REP:FAPXVP6L
Sara_Malovrh.pdf
1696754
Predstavitvena datoteka
2015-09-26 09:49:09