Repository of University of Nova Gorica

Search the repository
A+ | A- | Help | SLO | ENG

Query: search in
search in
search in
search in
* old and bolonia study programme

Options:
  Reset


131 - 138 / 138
First pagePrevious page567891011121314Next pageLast page
131.
Analysis of Data from Surface Detector Stations of the AugerPrime Upgrade
Lukas Zehrer, Marko Zavrtanik, Danilo Zavrtanik, Lili Yang, Serguei Vorobiov, Marta Trini, Samo Stanič, Gašper Kukec Mezek, Andrej Filipčič, Álvaro Taboada, 2019, published scientific conference contribution

Found in: ključnih besedah
Summary of found: ... Pierre Auger Observatory (PAO), ultra-high energy cosmic rays, AugerPrime...
Keywords: Pierre Auger Observatory (PAO), ultra-high energy cosmic rays, AugerPrime upgrade of the PAO, Scintillator Surface Detector (SSD), Water-Cherenkov Detectors (WCDs), AugerPrime data analysis
Published: 21.12.2020; Views: 644; Downloads: 21
.pdf Fulltext (2,56 MB)

132.
133.
134.
Working Group Report on the Combined Analysis of Muon Density Measurements from Eight Air Shower Experiments
Lukas Zehrer, Marko Zavrtanik, Danilo Zavrtanik, Lili Yang, Serguei Vorobiov, Marta Trini, Samo Stanič, Jon Paul Lundquist, Gašper Kukec Mezek, Andrej Filipčič, Lorenzo Cazon, 2019, published scientific conference contribution

Found in: ključnih besedah
Summary of found: ...EAS, EAS-MSU array, IceCube neutrino observatory, KASCADE-Grande, NEVOD-DECOR, Pierre Auger Observatory, SUGAR, Telescope Array, Yakutsk EAS...
Keywords: extensive air showers (EAS), muon density measurements in EAS, EAS-MSU array, IceCube neutrino observatory, KASCADE-Grande, NEVOD-DECOR, Pierre Auger Observatory, SUGAR, Telescope Array, Yakutsk EAS array
Published: 22.12.2020; Views: 638; Downloads: 28
.pdf Fulltext (620,78 KB)

135.
Search for Correlations of High-energy Neutrinos and Ultra-high Energy Cosmic Rays
Lukas Zehrer, Marko Zavrtanik, Danilo Zavrtanik, Lili Yang, Serguei Vorobiov, Marta Trini, Samo Stanič, Jon Paul Lundquist, Gašper Kukec Mezek, Andrej Filipčič, A.M. Barbano, 2019, published scientific conference contribution

Found in: ključnih besedah
Summary of found: ...trinos, arrival directions, correlation search, IceCube neutrino observatory, Pierre Auger Observatory, Telescope Array, ANTARES neutrino observatory...
Keywords: ultra-high energy cosmic rays (UHECR), high-energy neutrinos, arrival directions, correlation search, IceCube neutrino observatory, Pierre Auger Observatory, Telescope Array, ANTARES neutrino observatory
Published: 22.12.2020; Views: 657; Downloads: 22
.pdf Fulltext (400,93 KB)

136.
Calibration of the underground muon detector of the Pierre Auger Observatory
Lukas Zehrer, Marko Zavrtanik, Danilo Zavrtanik, Serguei Vorobiov, Marta Trini, Samo Stanič, Jon Paul Lundquist, Andrej Filipčič, A. Aab, 2021, original scientific article

Abstract: To obtain direct measurements of the muon content of extensive air showers with energy above 10[sup]16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m[sup]2-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m[sup]2 close to the intersection of the shower axis with the ground to much less than one per m[sup]2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.
Found in: ključnih besedah
Keywords: ultra-high energy cosmic rays, extensive air showers (EAS), EAS muonic component, Pierre Auger Observatory, underground muon detector, detector calibration
Published: 14.04.2021; Views: 442; Downloads: 32
URL Fulltext (0,00 KB)
This document has many files! More...

137.
138.
Search done in 0 sec.
Back to top