Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


41 - 50 / 138
Na začetekNa prejšnjo stran12345678910Na naslednjo stranNa konec
41.
42.
Thermal lens spectrometric detection in microfluidic systems
Mladen Franko, 2020, objavljeni znanstveni prispevek na konferenci (vabljeno predavanje)

Ključne besede: thermal lens, spectrometric detection, microfluidic systems
Objavljeno v RUNG: 17.12.2020; Ogledov: 2972; Prenosov: 12
URL Povezava na celotno besedilo
Gradivo ima več datotek! Več...

43.
Implementation of high performance liquid chromatography coupled to thermal lens spectrometry (HPLC‑TLS) for quantification of pyranoanthocyanins during fermentation of Pinot Noir grapes
Jelena Topič Božič, Lorena Butinar, Natka Ćurko, Karin Kovačević Ganić, Branka Mozetič Vodopivec, Dorota Korte, Mladen Franko, 2020, izvirni znanstveni članek

Opis: In this work high performance liquid chromatography coupled to thermal lens spectrometry (HPLC-TLS) was applied for monitoring of vinylphenolic pyranoanthocyanins formation during the fermentation of Pinot Noir wines. Vinylphenolic pyranoanthocyanins are wine pigments, present in low concentrations, but very important for wine colour stability. Fermentation process was conducted with four different yeast strains, used as starters, either in sequential fermentation of non-Saccharomyces with S. cerevisiae yeast or as single fermentation with S. cerevisiae yeasts in order to test the applicability of developed method for monitoring of selected compounds in real wine fermentation experiments. The developed HPLC-TLS method showed higher sensitivity compared to HPLC coupled to diode array detection (DAD) technique for particular wine colour compounds. Obtained limits of detection (LODs), were 6- and 22-times lower in comparison to HPLC–DAD in gradient and isocratic elution mode, respectively, whereas limits of quantification (LOQs) 5 and 18-times lower. Lower LODs enabled earlier observation of vinylphenolic pyranoanthocyanins formation during fermentation (already at day 7) in the case of HPLC-TLS method in gradient mode, while by using HPLC–DAD in gradient elution mode the formation of vinylphenolic pyranoanthocyanins was noticed only after 12 days of fermentation.
Ključne besede: Thermal lens spectrometry (TLS), High performance liquid chromatography (HPLC), Pyranoanthocyanins, Wine, Yeasts
Objavljeno v RUNG: 18.06.2020; Ogledov: 3306; Prenosov: 0
Gradivo ima več datotek! Več...

44.
45.
Thermal Effusivity Investigations of Solid Thermoelectrics Using the Front Photopyroelectric Detection
Carmen Tripon, Dorin Dadarlat, Katalin Kovacs, Victor Petru Tosa, Mladen Franko, 2020, izvirni znanstveni članek

Opis: The front photopyroelectric configuration (FPPE), making use of air as a coupling fluid between the sample and sensor, was applied to measure the thermal effusivity of some solid thermoelectric materials. The investigated samples were ZnO, CuCrO2, Cu4Sn7S16, TiS3 and two samples of high manganese silicide (HMS) thermoelectric materials. Most of these materials are porous and consequently, the classical PPE method, making use of standard coupling fluids between sensor and sample, cannot be used due to the fact that the coupling fluid penetrates inside the sample and leads to incorrect results. With this work we extend (to thermoelectric solids) the area of application of a method, recently proposed by Salazar et al. (Measurement 121: 96, 2018). Experimentally, the thermal effusivity is obtained from a multi-parametric fit of the phase of the FPPE signal as a function of the modulation frequency (with sample’s thermal effusivity, thickness of the sensor-sample air gap and heat losses by convection and radiation, as fitting parameters). It was demonstrated that, in some particular cases, the three parameters are independent and consequently, the solution of the fit is unique. Where possible, the obtained results have been compared with data from the literature and good agreement was found.
Ključne besede: Front photopyroelectric configuration (FPPE), Solid thermoelectrics, Thermal effusivity
Objavljeno v RUNG: 02.05.2020; Ogledov: 2700; Prenosov: 0
Gradivo ima več datotek! Več...

46.
Determination of total ChE and AChE activity in human serum by FIA-TLS
Andrej Jerkič, Tjaša Birsa, Dorota Korte, Martina Bergant Marušič, Mladen Franko, 2019, objavljeni povzetek znanstvenega prispevka na konferenci

Ključne besede: acetylcholinesterase, FIA-TLS, butyrilcholinesterase
Objavljeno v RUNG: 19.12.2019; Ogledov: 3353; Prenosov: 0
Gradivo ima več datotek! Več...

47.
Determination of Iron in Environmental Water Samples by FIA-TLS
Miha Tomšič, Leja Goljat, Hanna Budasheva, Dorota Korte, Arne Bratkič, Mladen Franko, 2019, izvirni znanstveni članek

Opis: The determination of low concentration of iron in natural waters can be difficult due to the complexity of natural water, but primarily because it requires preconcentration of the sample with solvent extraction. In this work we report on results of thermal lens spectrometry (TLS) coupled to flow injection analysis (FIA) as a highly sensitive FIA-TLS method of iron detection. The concentration of iron redox species was determined using 1,10-phenanthroline (PHN), that forms stable complexes with Fe(II) ions which are characterized by an absorption maximum at 508 nm. The TLS system using a 633 nm probe laser and 530 nm pump laser beam was exploited for on-line detection in flow injection analysis, where a PHN solution was used as the carrier solution for FIA. The concentration of the complexing agent affects the quality of the TLS signal, and the optimal concentration was found at 1 mM PHN. The achieved limits of detection (LODs) for Fe(II) and total iron were 33 nM for Fe(II) and 21 nM for total iron concentration. The method was further validated by determining the linear concentration range, specificity in terms of analytical yield and by determining concentration of iron in a water sample from a local water stream.
Ključne besede: Flow injection analysis, iron concentration, thermal lens spectroscopy
Objavljeno v RUNG: 18.12.2019; Ogledov: 3258; Prenosov: 105
.pdf Celotno besedilo (690,39 KB)

48.
A multi-thermal-lens approach to evaluation of multi-pass probe beam configuration in thermal lens spectrometry
Humberto Cabrera, Leja Goljat, Dorota Korte, Ernesto Marin, Mladen Franko, izvirni znanstveni članek

Opis: In this work, a recently proposed thermal lens instrument based on multi-pass probe beam concept is investigated and described as a multi-thermal-lens equivalent system. A simulation of the photothermal lens signal formation in a multi-thermal-lens equivalent configuration of the system is performed and validated by comparing the experimental signals of single, dual and ten-pass configurations to theoretically calculated values. The theoretically predicted enhancement of the signal is 9 to 10-fold for a weak thermal lens when comparing the ten-pass configuration with the conventional single-pass thermal lens system. Experimentally achieved signal enhancement in the ten-pass system is 8.3 for pure ethanol sample and between 8 and 9 for solutions with different concentrations of the Fe(II) - 1,10-Phenanthroline complex. Additionally, a value of 9.1 was calculated as the ratio of the slopes of the calibration lines obtained using the ten-pass and single-pass configurations. The achieved limit of detection for determination of Fe(II), in the ten-pass configuration, was 0.4 µgL-1, with a relative standard deviation around 4.5%, which compares favorably with previously reported results for TLS determination of Fe(II) in thin samples using low excitation power. For the multi-pass configuration the linear range of measurement is reduced when compared to the single-pass configuration. This is explained by the theoretical analysis of the photothermal signal under multi-pass condition, which shows the important contribution of the nonlinear term in the theoretical expression for the photothermal signal. The ten-pass configuration, which is presented and validated experimentally for the first time, offers important signal enhancement needed in recently developed TLS instruments with tunable, low power excitation sources.
Ključne besede: Thermal lens spectrometry, Photothermal detection, Trace determination, Chemical sensor
Objavljeno v RUNG: 10.12.2019; Ogledov: 3236; Prenosov: 0
Gradivo ima več datotek! Več...

49.
50.
Iskanje izvedeno v 0.07 sek.
Na vrh