Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 4 / 4
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Consistent determination of the heating rate of light-absorbing aerosol using wavelength- and time-dependent Aethalometer multiple-scattering correction
Luca Ferrero, Vera Bernardoni, Luca Santagostini, Sergio Cogliati, Francesca Soldan, Sara Valentini, Dario Massabò, Griša Močnik, Asta Gregorič, Martin Rigler, 2021, izvirni znanstveni članek

Opis: Accurate and temporally consistent measurements of light absorbing aerosol (LAA) heating rate (HR) and of its source apportionment (fossil-fuel, FF; biomass-burning, BB) and speciation (black and brown Carbon; BC, BrC) are needed to evaluate LAA short-term climate forcing. For this purpose, wavelength- and time-dependent accurate LAA absorption coefficients are required. HR was experimentally determined and apportioned (sources/species) in the EMEP/ACTRIS/COLOSSAL-2018 winter campaign in Milan (urban-background site). Two Aethalometers (AE31/AE33) were installed together with a MAAP, CPC, OPC, a low volume sampler (PM2.5) and radiation instruments. AE31/AE33 multiple-scattering correction factors (C) were determined using two reference systems for the absorption coefficient: 1) 5-wavelength PP_UniMI with low time resolution (12 h, applied to PM2.5 samples); 2) timely-resolved MAAP data at a single wavelength. Using wavelength- and time-independent C values for the AE31 and AE33 obtained with the same reference device, the total HR showed a consistency (i.e. reproducibility) with average values comparable at 95% probability. However, if different reference devices/approaches are used, i.e. MAAP is chosen as reference instead of a PP_UniMI, the HR can be overestimated by 23-30% factor (by both AE31/AE33). This became more evident focusing on HR apportionment: AE33 data (corrected by a wavelength- and time-independent C) showed higher HRFF (+24±1%) and higher HRBC (+10±1%) than that of AE31. Conversely, HRBB and HRBrC were -28±1% and -29±1% lower for AE33 compared to AE31. These inconsistencies were overcome by introducing a wavelength-dependent Cλ for both AE31 and AE33, or using multi-wavelength apportionment methods, highlighting the need for further studies on the influence of wavelength corrections for HR determination. Finally, the temporally-resolved determination of C resulted in a diurnal cycle of the HR not statistically different whatever the source- speciation- apportionment used.
Ključne besede: climate change, heating rate, black carbon, light absorbing aerosols
Objavljeno v RUNG: 09.06.2021; Ogledov: 1997; Prenosov: 0
Gradivo ima več datotek! Več...

2.
Determination of Aethalometer multiple-scattering enhancement parameters and impact on source apportionment during the winter 2017/18 EMEP/ACTRIS/COLOSSAL campaign in Milan
Vera Bernardoni, Luca Ferrero, Ezio Bolzacchini, Alice Corina Forello, Asta Gregorič, Dario Massabo, Griša Močnik, Paolo Prati, Martin Rigler, Luca Santagostini, 2021, izvirni znanstveni članek

Opis: In the frame of the EMEP/ACTRIS/COLOSSAL campaign in Milan during winter 2018, equivalent black carbon measurements using the Aethalometer 31 (AE31), the Aethalometer 33 (AE33), and a Multi-Angle Absorption Photometer (MAAP) were carried out together with levoglucosan analyses on 12 h resolved PM2.5 samples collected in parallel. From AE31 and AE33 data, the loading-corrected aerosol attenuation coefficients (bATN) were calculated at seven wavelengths (λ, where λ values are 370, 470, 520, 590, 660, 880, and 950 nm). The aerosol absorption coefficient at 637 nm (babs_MAAP) was determined by MAAP measurements. Furthermore, babs was also measured at four wavelengths (405, 532, 635, 780 nm) on the 12 h resolved PM2.5 samples by a polar photometer (PP_UniMI). After comparing PP_UniMI and MAAP results, we exploited PP_UniMI data to evaluate the filter multiple-scattering enhancement parameter at different wavelengths for AE31 and AE33. We obtained instrument- and wavelength-dependent multiple-scattering enhancement parameters by linear regression of the Aethalometer bATN against the babs measured by PP_UniMI. We found significant dependence of the multiple-scattering enhancement parameter on filter material, hence on the instrument, with a difference of up to 30 % between the AE31 and the AE33 tapes. The wavelength dependence and day–night variations were small – the difference between the smallest and largest value was up to 6 %. Data from the different instruments were used as input to the so-called “Aethalometer model” for optical source apportionment, and instrument dependence of the results was investigated. Inconsistencies among the source apportionment were found fixing the AE31 and AE33 multiple-scattering enhancement parameters to their usual values. In contrast, optimised multiple-scattering enhancement parameters led to a 5 % agreement among the approaches. Also, the component apportionment “MWAA model” (Multi-Wavelength Absorption Analyzer model) was applied to the dataset. It was less sensitive to the instrument and the number of wavelengths, whereas significant differences in the determination of the absorption Ångström exponent for brown carbon were found (up to 22 %).
Ključne besede: black carbon, filter photometer, Aethalometer, source apportionment
Objavljeno v RUNG: 16.04.2021; Ogledov: 2214; Prenosov: 0
Gradivo ima več datotek! Več...

3.
An extracellular polymeric substance quickly chelates mercury(II) with N-heterocyclic groups
Franco Baldi, Michele Gallo, Salvatore Daniale, Dario Battistel, Claudia Faleri, Alojz Kodre, Iztok Arčon, 2017, izvirni znanstveni članek

Opis: A strain of Klebsiella oxytoca DSM 29614 is grown on sodium citrate in the presence of 50 mg l−1 of Hg as Hg(NO3)2. During growth, the strain produces an extracellular polymeric substance (EPS), constituted by a mixture of proteins and a specific exopolysaccharide. The protein components, derived from the outer membrane of cells, are co-extracted with the extracellular exopolysaccharide using ethanol. The extracted EPS contains 7.5% of Hg (total amount). This indicates that EPS is an excellent material for the biosorption of Hg2+, through chemical complexation with the EPS components. The binding capacity of these species towards Hg2+ is studied by cyclic voltammetry, and Hg L3-edge XANES and EXAFS spectroscopy. The results found indicate that Hg2+ is mainly bound to the nitrogen of the imidazole ring or other N-heterocycle compounds. The hydroxyl moities of sugars and/or the carboxyl groups of two glucuronic acids in the polysaccharide can also play an important role in sequestring Hg2+ ions. However, N-heterocyclic groups of proteins bind Hg2+ faster than hydroxyl and carboxyl groups of the polysaccharide.
Ključne besede: Klebsiella oxytoca, Biosorption, Proteins, Polysaccharide, Cyclic voltammetry, EXAFS analysis
Objavljeno v RUNG: 03.03.2017; Ogledov: 4561; Prenosov: 0
Gradivo ima več datotek! Več...

4.
Iskanje izvedeno v 0.02 sek.
Na vrh