Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 3 / 3
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Chemical characterization of PM2.5 and source apportionment of organic aerosol in New Delhi, India
Anna Tobler, Deepika Bhattu, Francesco Canonaco, Vipul Lalchandani, Ashutosh Shukla, Navaneeth Thamban, Suneeti Mishra, Atul Srivastava, Deewan Bisht, Suresh Tiwari, Surender Singh, Griša Močnik, Urs Baltensperger, Sachchida Tripathi, J. G. Slowik, André S. H. Prévôt, 2020, izvirni znanstveni članek

Opis: Delhi is one of the most polluted cities worldwide and a comprehensive understanding and deeper insight into the air pollution and its sources is of high importance. We report 5 months of highly time-resolved measurements of non-refractory PM2.5 and black carbon (BC). Additionally, source apportionment based on positive matrix factorization (PMF) of the organic aerosol (OA) fraction is presented. The highest pollution levels are observed during winter in December/January. During that time, also uniquely high chloride concentrations are measured, which are sometimes even the most dominant NR-species in the morning hours. With increasing temperature, the total PM2.5 concentration decreases steadily, whereas the chloride concentrations decrease sharply. The concentrations measured in May are roughly 6 times lower than in December/January. PMF analysis resolves two primary factors, namely hydrocarbon-like (traffic-related) OA (HOA) and solid fuel combustion OA (SFC-OA), and one or two secondary factors depending on the season. The uncertainties of the PMF analysis are assessed by combining the random a-value approach and the bootstrap resampling technique of the PMF input. The uncertainties for the resolved factors range from ±18% to ±19% for HOA, ±7% to ±19% for SFC-OA and ±6 % to ±11% for the OOAs. The average correlation of HOA with eBCtr is R2 = 0.40, while SFC-OA has a correlation of R2 = 0.78 with eBCsf. Anthracene (m/z 178) and pyrene (m/z 202) (PAHs) are mostly explained by SFC-OA and follow its diurnal trend (R2 = 0.98 and R2 = 0.97). The secondary oxygenated aerosols are dominant during daytime. The average contribution during the afternoon hours (1 pm–5 pm) is 59% to the total OA mass, with contributions up to 96% in May. In contrast, the primary sources are more important during nighttime: the mean nightly contribution (22 pm–3 am) to the total OA mass is 48%, with contributions up to 88% during some episodes in April.
Ključne besede: New Delhi, PM2.5, Source apportionment, PMF
Objavljeno v RUNG: 20.07.2020; Ogledov: 2462; Prenosov: 0
Gradivo ima več datotek! Več...

2.
3.
Iskanje izvedeno v 0.02 sek.
Na vrh