Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 5 / 5
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
[Predstavitev znanstvenega dosežka Trans2Care]
2013, radijski ali tv dogodek

Najdeno v: osebi
Ključne besede: prosti biblirubin, HPLC, TLS
Objavljeno: 25.04.2014; Ogledov: 1983; Prenosov: 8
URL Polno besedilo (0,00 KB)

2.
Application of high-performance liquid chromatography combined with ultra-sensitive thermal lens spectrometric detection for simultaneous biliverdin and bilirubin assessment at trace levels in human serum
Mitja Martelanc, Lovro Žiberna, Sabina Passamonti, Mladen Franko, 2016, izvirni znanstveni članek

Opis: We present the applicability of a new ultra sensitive analytical method for the simultaneous determination of biliverdin and bilirubin in human serum. The method comprises isocratic reversed-phase(RP) C18 high-performance liquid chromatography (HPLC) and thermal lens spectrometric detection (TLS)based on excitation by a krypton laser emission line at 407 nm. This method enables the separation of IX-α biliverdin and IX-α bilirubin in 11 min. with limit of detection (LOD) and limit of quantitation (LOQ) for biliverdin of 1.2 nM and 3 nM, and 1nM and 2.8 nM for bilirubin,respectively.In addition, a step-gradient elution was set up, by changing the mobile phase composition, in order to further enhance the sensitivity for bilirubin determination with LOD and LOQ of 0.5 nM and 1.5 nM, respectively. In parallel, an isocraticHPLC-DAD method was developed for benchmarking against HPLC-TLS methods. The LOD and LOQ forbiliverdin were 6 nM and 18 nM, and 2.5 nM and 8nM for bilirubin,respectively. Additionally, both isocratic methods were applied for measuring biliverdin and free bilirubin in human serum samples (from 2 male and 2 female healthy donors). Combining isocratic HPLC method with TLS detector was crucial for first ever biliverdin determination in serum together with simultaneous free bilirubin determination. We showed for the first time the concentration ratio of free bilirubin versus unbound biliverdin in human serum samples.
Najdeno v: osebi
Ključne besede: Bilirubin, biliverdin, serum, HPLC, TLS
Objavljeno: 29.03.2016; Ogledov: 2092; Prenosov: 0
.pdf Polno besedilo (964,28 KB)

3.
Bilirubin is an Endogenous Antioxidant in Human Vascular Endothelial Cells
Lovro Žiberna, Mitja Martelanc, Mladen Franko, Sabina Passamonti, 2016, izvirni znanstveni članek

Opis: Bilirubin is a standard serum biomarker of liver function. Inexplicably, it is inversely correlated with cardiovascular disease risk. Given the role of endothelial dysfunction in originating cardiovascular diseases, direct analysis of bilirubin in the vascular endothelium would shed light on these relationships. Hence, we used high-performance liquid chromatography coupled with thermal lens spectrometric detection and diode array detection for the determination of endogenous cellular IXα-bilirubin. To confirm the isomer IXα-bilirubin, we used ultra-performance liquid chromatography coupled with a high-resolution mass spectrometer using an electrospray ionization source, as well as tandem mass spectrometric detection. We measured bilirubin in both arterial and venous rat endothelium (0.9–1.5 pmol mg−1 protein). In the human endothelial Ea.hy926 cell line, we demonstrated that intracellular bilirubin (3–5 pmol mg−1 protein) could be modulated by either extracellular bilirubin uptake, or by up-regulation of heme oxygenase-1, a cellular enzyme related to endogenous bilirubin synthesis. Moreover, we determined intracellular antioxidant activity by bilirubin, with EC50 = 11.4 ± 0.2 nM, in the range of reported values of free serum bilirubin (8.5–13.1 nM). Biliverdin showed similar antioxidant properties as bilirubin. We infer from these observations that intra-endothelial bilirubin oscillates, and may thus be a dynamic factor of the endothelial function.
Najdeno v: osebi
Ključne besede: Antioxidants, bilirubin, endothelial cells
Objavljeno: 07.07.2016; Ogledov: 1890; Prenosov: 190
.pdf Polno besedilo (585,86 KB)

4.
Highly Sensitive Determination of Pyoverdine in Cloud Water by HPLC-Thermal Lens Spectrometry
Leja Goljat, Mitja Martelanc, Virginie Vinatier, Anne-Marie Delort, Mladen Franko, 2016, objavljeni povzetek znanstvenega prispevka na konferenci

Opis: New method for pyoverdine and Fe(III)-pyoverdine detection was developed. Two isomers of pyoverdine and two isomers of Fe(III)-pyoverdine were separated isocraticaly on reversed-phase (RP)-C18 chromatograhic column and detected by DAD, FLD and TLS. HPLC-TLS method enables separation and determination of pyoverdine and Fe(III)-pyoverdine in a single run and excels in superior sensitivities when compared to conventional HPLC-DAD system.
Najdeno v: osebi
Ključne besede: Pyoverdine, Fe(III)-pyoverdine, cloud water, high-performance liquid chromatography, thermal lens spectrometry
Objavljeno: 04.07.2016; Ogledov: 1911; Prenosov: 0

5.
NOVEL APPROACHES FOR THE DETERMINATION OF BIOGENIC AMINES IN FOOD SAMPLES
Sara Budal, Mitja Martelanc, Mojca Žorž, Mladen Franko, 2017, izvirni znanstveni članek

Opis: In this work, new analytical approaches for determination of biogenic amines in wines were developed. For the first time, we studied the derivatization of BAs in wines with naphthalene- 2,3-dicarboxaldehyde (NDA) and with dabsyl chloride (DBS) and analysis of derivatized BAs by HPLC coupled to fluorescence (HPLC-NDA-FL) and thermal lens spectrometry (HPLC-DBS-TLS) detectors. The sensitivity of the two methods (LODs HPLC-NDA-FL in the range 27-73 μg/L; LODs HPLC-DBS-TLS in the range 3.4-11 μg/L) was higher than that of the official method for biogenic amines in wines, OIV-MA-AS315-18 (60-77 μg/L). For its best performances, the HPLC-DBS-TLS technique was applied to the analysis of putrescine, cadaverine, histamine and tyramine in two white wine samples. Additionally, exploiting the Berthelot reaction, the TLS fast screening of biogenic amines in wines, following the release of ammonia by transglutaminase, was also proposed. This approach allowed us to determine total biogenic amount content in concentrations below 0.1 mg/L, expressed as equivalents of histamine.
Najdeno v: osebi
Ključne besede: biogenic amines, NDA, liquid chromatography, TLS, fluorescence, wine
Objavljeno: 02.11.2017; Ogledov: 1191; Prenosov: 81
.pdf Polno besedilo (441,06 KB)

Iskanje izvedeno v 0 sek.