Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 3 / 3
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
TD/GC–MS analysis of volatile markers emitted from mono- and co-cultures of Enterobacter cloacae and Pseudomonas aeruginosa in artificial sputum
Craig Portsmouth, Pedro Povoa, Jan H Leopold, Pouline M P van Oort, Emili Diaz, Gemma Goma, Timothy Felton, Paul Dark, Alan Davie, Luis Coelho, Lieuwe D Bos, Marta Camprubi, Antonio Artigas, Jonathan Barnard-Smith, Waqar M Ahmed, Stephen J Fowler, Tamara M E Nijsen, Royston Goodacre, Weda Hans, Hugo knobel, Oluwasola Lawal, Iain R White, 2018, izvirni znanstveni članek

Opis: Introduction: Infections such as ventilator-associated pneumonia (VAP) can be caused by one or more pathogens. Current methods for identifying these pathogenic microbes often require invasive sampling, and can be time consuming, due to the requirement for prolonged cultural enrichment along with selective and differential plating steps. This results in delays in diagnosis which in such critically ill patients can have potentially life-threatening consequences. Therefore, a non-invasive and timely diagnostic method is required. Detection of microbial volatile organic compounds (VOCs) in exhaled breath is proposed as an alternative method for identifying these pathogens and may distinguish between mono- and poly-microbial infections. Objectives: To investigate volatile metabolites that discriminate between bacterial mono- and co-cultures. Methods: VAP-associated pathogens Enterobacter cloacae and Pseudomonas aeruginosa were cultured individually and together in artificial sputum medium for 24 h and their headspace was analysed for potential discriminatory VOCs by thermal desorption gas chromatography–mass spectrometry. Results: Of the 70 VOCs putatively identified, 23 were found to significantly increase during bacterial culture (i.e. likely to be released during metabolism) and 13 decreased (i.e. likely consumed during metabolism). The other VOCs showed no transformation (similar concentrations observed as in the medium). Bacteria-specific VOCs including 2-methyl-1-propanol, 2-phenylethanol, and 3-methyl-1-butanol were observed in the headspace of axenic cultures of E. cloacae, and methyl 2-ethylhexanoate in the headspace of P. aeruginosa cultures which is novel to this investigation. Previously reported VOCs 1-undecene and pyrrole were also detected. The metabolites 2-methylbutyl acetate and methyl 2-methylbutyrate, which are reported to exhibit antimicrobial activity, were elevated in co-culture only. Conclusion: The observed VOCs were able to differentiate axenic and co-cultures. Validation of these markers in exhaled breath specimens could prove useful for timely pathogen identification and infection type diagnosis.
Najdeno v: osebi
Ključne besede: Bacteria, Enterobacter cloacae, Gas Chromatography-Mass Spectrometry, Infection, Pseudomonas aeruginosa, Volatile organic compounds
Objavljeno: 18.07.2019; Ogledov: 712; Prenosov: 37
.pdf Polno besedilo (1,29 MB)

2.
Exhaled breath metabolomics reveals a pathogen-specific response in a rat pneumonia model for two human pathogenic bacteria: a proof-of-concept study
Iain R White, Pouline M van Oort, 2019, izvirni znanstveni članek

Opis: Volatile organic compounds in breath can reflect host and pathogen metabolism and might be used to diagnose pneumonia. We hypothesized that rats with Streptococcus pneumoniae (SP) or Pseudomonas aeruginosa (PA) pneumonia can be discriminated from uninfected controls by thermal desorption-gas chromatography-mass-spectrometry (TD-GC-MS) and selected ion flow tube-mass spectrometry (SIFT-MS) of exhaled breath. Male adult rats (n = 50) received an intratracheal inoculation of 1) 200 µl saline, or 2) 1 × 107 colony-forming units of SP or 3) 1 × 107 CFU of PA. Twenty-four hours later the rats were anaesthetized, tracheotomized, and mechanically ventilated. Exhaled breath was analyzed via TD-GC-MS and SIFT-MS. Area under the receiver operating characteristic curves (AUROCCs) and correct classification rate (CCRs) were calculated after leave-one-out cross-validation of sparse partial least squares-discriminant analysis. Analysis of GC-MS data showed an AUROCC (95% confidence interval) of 0.85 (0.73-0.96) and CCR of 94.6% for infected versus noninfected animals, AUROCC of 0.98 (0.94-1) and CCR of 99.9% for SP versus PA, 0.92 (0.83-1.00), CCR of 98.1% for SP versus controls and 0.97 (0.92-1.00), and CCR of 99.9% for PA versus controls. For these comparisons the SIFT-MS data showed AUROCCs of 0.54, 0.89, 0.63, and 0.79, respectively. Exhaled breath analysis discriminated between respiratory infection and no infection but with even better accuracy between specific pathogens. Future clinical studies should not only focus on the presence of respiratory infection but also on the discrimination between specific pathogens.
Najdeno v: osebi
Ključne besede: biomarkers, exhaled breath analysis, infection, pneumonia
Objavljeno: 22.07.2019; Ogledov: 748; Prenosov: 0
.pdf Polno besedilo (320,58 KB)

3.
Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients–comparison of two sampling methods
Iain R. White, Pouline M. van Oort, Waqar Ahmed, Craig Johnson, Jonathan Bannard-Smith, Timothy Felton, Lieuwe D. Bos, Royston Goodacre, Paul Dark, Stephen J. Fowler, 2020, izvirni znanstveni članek

Opis: Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in “real life” in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure–volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of data analysed above the MDL. The relative performance of the two methods differed depending on the VOC under study and both methods showed sensitivity towards different exhaled VOCs. Furthermore, method performance differed depending on recruitment site, as the centres were equipped with different brands of respiratory equipment, an important consideration for the design of multicentre studies investigating exhaled VOCs in mechanically ventilated patients.
Najdeno v: osebi
Ključne besede: Volatile organic compounds, infection, breath, ventilator associated pneumonia
Objavljeno: 10.12.2020; Ogledov: 104; Prenosov: 0
.pdf Polno besedilo (1,61 MB)

Iskanje izvedeno v 0 sek.
Na vrh