Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 2 / 2
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
“LESSONS LEARNED” (PARTIAL TEST DEPLOYMENTS REPORT)
Tomislav Brajnović,, Peter Purg, Daniela Brasil, Alessandro Bordina, Miljana Babić, 2014, druge monografije in druga zaključena dela

Opis: The report consist of individual test-run reports by participating teachers and consortium-level observers that gathered qualitative and quantitative data through short interviews, surveys and QA questionnaires mostly with students, but also among themselves. A joint evaluation is delivered and a “lessons learned” compendium published, offered digitally through the project’s dissemination system (mostly newsletter and website-promotion), and spread locally through the teaching communities – also partly entering the professional article as “experience report” (see next deliverable). These reports and the “lessons learned” were discussed and confirmed in the below structure at the September 2013 meeting, organised by P4. Notably, a total of three sceintific or porfessional articles were (to be) published (as separate deliverables) refereing to the lessons learned in this project, refering to the summative experience of the project.
Najdeno v: ključnih besedah
Ključne besede: Curriculum, module, course, study programme, degree, international, comparison, study, national, studio, MA
Objavljeno: 05.07.2016; Ogledov: 795; Prenosov: 42
URL Polno besedilo (0,00 KB)
Gradivo ima več datotek! Več...

2.
ASSESSMENT OF EFFECTIVE DOSES BASED ON VARIOUS RADON MEASURING TECHNIQUES
Nataša Smrekar, 2016, magistrsko delo

Opis: In my master's thesis, I have focused on radon gas in 43 buildings used for different purposes (23 schools, 3 kindergartens, 16 offices and a residential house) in which preliminary measurements had shown higher concentrations of radon gas. I carried out measurements of radon and short-lived radon products whilst simultaneously employing different measurement techniques. In all 43 buildings, I measured the instantaneous concentration of radon by using scintillation cells; in 18 buildings, I additionally measured the average concentration of radon by using solid state nuclear track detectors and in 10 buildings, I measured concentration retrospectively with solid state nuclear track detectors. In four selected buildings (a school, a kindergarten, an office and a residential house), I carried out the measurements by using all of the available equipment. I monitored the daily fluctuations of concentration of radon and short-lived radon products by using continuous monitors in 14 buildings. This is how I obtained the factor of radioactive equilibrium between radon and its short-lived products. Based on the results obtained, I calculated the effective doses. As the basis for calculating the doses, I used the instantaneous and average concentrations of radon and the equilibrium factor taken from literature (0.40) or own measurements. I compared the doses and critically evaluated them. In contrast to the previous research, I researched radon exclusively in areas with increased risk for radon. I studied the influence of the working regime on the concentration of radon in different working environments (i.e. a school, a kindergarten and an office).
Najdeno v: ključnih besedah
Ključne besede: Radon, short-lived radon products, measurement technique, scintillation cell, solid-state nuclear track detector, retrospective detector, equilibrium factor, effective dose, comparison.
Objavljeno: 28.09.2016; Ogledov: 941; Prenosov: 76
.pdf Polno besedilo (1,86 MB)

Iskanje izvedeno v 0 sek.
Na vrh