Naslov: | Trace Detection and Photothermal Spectral Characterization by a Tuneable Thermal Lens Spectrometer with White-Light Excitation |
---|
Avtorji: | ID Cabrera, Humberto, ICTP (Avtor) ID Korte, Dorota, UNG-LELS (Avtor) ID Franko, Mladen, UNG-LELS (Avtor), et al. |
Datoteke: |
Gradivo nima datotek, ki so prostodostopne za javnost. Gradivo je morda fizično dosegljivo v knjižnici fakultete, zalogo lahko preverite v COBISS-u. |
---|
Jezik: | Angleški jezik |
---|
Vrsta gradiva: | Delo ni kategorizirano |
---|
Tipologija: | 1.01 - Izvirni znanstveni članek |
---|
Organizacija: | UNG - Univerza v Novi Gorici
|
---|
Opis: | In the thermal lens experimental set-up we replaced the commonly employed pump laser by a halogen lamp, combined with an interference lter, providing a tuneable, nearly monochromatic pump source over the range of wavelengths 430–710 nm. Counter-propagating pump and probe beams are used and a 1 mm path-length sam- ple cell together with the interference lter makes an optical cavity, providing ampli cation of the thermal lens signal, which leads to enhancement of the measurement sensitivity, and enables detection of absorbances on the order of 5×10− 6. Ampli ed thermal lens signal allows us to replace the typical lock-in ampli er and digital os- cilloscope with a silicon photodetector, Arduino board, and a personal computer, offering the possibility for a compact, robust and portable device, useful for in- eld absorption measurements in low concentration or weakly absorbing species. The use of a white light source for optical pumping, an interference lter for wavelength selection and direct diagnostic of the thermal lens signal increase the versatility of the instrument and simpli- es substantially the experimental setup. Determination of Fe(II) concentrations at parts per billion levels was performed by the described white-light thermal lens spectrophotometer and the absorption spectrum for 50μg/ L Fe(II)-1,10-phenanthroline was well reproduced with an average measurement precision of 4%. The obtained limits of detection and quantitation of Fe(II) determination at 510nm are 3μgL− 1 and 11μgL− 1, respectively. The calibration curve was linear in the concentration range of LOQ-500μgL− 1 with reproducibility between 2% and 6%, con rming that this instrument provides good spectrometric capabilities such as high sensitivity, tune- ability and good reproducibility. In addition, the versatility of the instrument was demonstrated by recording the photothermal spectrum of gold nanostructured material and determination of excitation wavelength with most ef cient optical to thermal energy conversion, which differs considerably (cca 100 nm) from the absorption maximum of the investigated sample. |
---|
Ključne besede: | thermal lens spectrometry, Fe(II) determination, photothermal technique, multi-wavelength excitation |
---|
Verzija publikacije: | Objavljena publikacija |
---|
Leto izida: | 2018 |
---|
Št. strani: | 7 |
---|
Številčenje: | 0 |
---|
PID: | 20.500.12556/RUNG-3840-69172996-ba4a-a86b-6aaf-8d04ea44bcb7 |
---|
COBISS.SI-ID: | 5110011 |
---|
DOI: | https://doi.org/10.1016/j.talanta.2018.02.073 |
---|
NUK URN: | URN:SI:UNG:REP:QGZBGI0C |
---|
Datum objave v RUNG: | 21.02.2018 |
---|
Število ogledov: | 5122 |
---|
Število prenosov: | 0 |
---|
Metapodatki: | |
---|
:
|
Kopiraj citat |
---|
| | | Skupna ocena: | (0 glasov) |
---|
Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
---|
Objavi na: | |
---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |