Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


41 - 50 / 73
Na začetekNa prejšnjo stran12345678Na naslednjo stranNa konec
41.
Določevanje železa v naravnih vodah s tehniko FIA-TLS
Gaja Tomsič, 2019, magistrsko delo

Opis: Vodni organizmi potrebujejo železo za bistvene metabolne procese. Vendar pa se večina raztopljenega železa v vodi, ki ni vezana na organske molekule ali kompleksirana z anorganskimi ligandi, oksidira v železove ione Fe(III) in tvori oborino Fe(OH)3. Zato je aktivnost biomase na vodni gladini pogosto omejena z razpoložljivostjo raztopljenega železa, ki je lahko nižja od 1 nM. To dejstvo lahko vpliva tudi na širše okolje, saj ima vpliv na hitrost fiksiranja CO2 zaradi fotosinteze avtotrofne biomase. Določanje elementov v sledovih, med katerimi je tudi železo, predstavlja zaradi kompleksnosti naravne vode izziv. Določitev koncentracije železa je v preteklosti zahtevala predhodno koncentracijo vzorca z ekstrakcijo s topilom. V tem delu poročamo o rezultatih spektrometrije s toplotnimi lečami s pretočno injekcijsko analizo, ki ne potrebuje predkoncentracije železa v vzorcu. Koncentracije železa v različnih redoks oblikah smo določali s pretočno injekcijsko analizo (FIA) z uporabo 1,10 - fenantrolina, ki kompleksira železove Fe(II) ione v stabilen kompleks z absorpcijskim maksimumom pri 508 nm. Skupno količino raztopljenega železa (Fe(II) in Fe(III)) smo določili po redukciji Fe(III) iona v Fe(II) z askorbinsko kislino. V sistemu FIA smo za detekcijo uporabili spektrometer s toplotnimi lečami (TLS); tipalni žarek je imel valovno dolžino 633 nm, vzbujevalni pa 450 nm ali 530 nm. Posledica absorpcije svetlobe vzbujevalnega žarka je segrevanje vzorca zaradi neradiacijske relaksacije absorbirane energije. Tvori se toplotna leča (TL). Detekcija temelji na razprševanju tipalnega žarka na TL. Analize vzorcev smo izvajali v »šaržnem« in »on-line« načinu. Z »on-line« konfiguracijo (1,10 - fenantrolin je sestavljal nosilno raztopino za FIA) smo lahko injicirali vzorce brez kakršnekoli predhodne priprave ali dodajanja reagentov, razen askorbinske kisline pri določevanju skupnega železa. V tem magistrskem delu smo primerjali spodnje meje detekcije (LOD) različnih tehnik in pogojev (valovne dolžine laserske svetlobe in koncentracija nosilne raztopine v pretočnem sistemu) s ciljem, da bi dosegli najboljšo občutljivost za železove ione. FIA-TLS je primerna tudi za tehniko standardnega dodatka. Uporabnost in pravilnost FIA-TLS smo preverili z določevanjem koncentracij železa v rečni vodi.
Najdeno v: osebi
Ključne besede: železove zvrsti, pretočna injekcijska analiza (FIA), spektrometrija s toplotnimi lečami (TLS)
Objavljeno: 19.02.2019; Ogledov: 2862; Prenosov: 106
.pdf Polno besedilo (2,30 MB)

42.
43.
Determination of bioavailable Fe redox fractions of sediment pore waters by DGT passive sampling and BDS detection
Mladen Franko, Arne Bratkič, Dorota Korte, Hanna Budasheva, 2019, objavljeni povzetek znanstvenega prispevka na konferenci

Opis: The bioavailability and toxicity of contaminants in sediments to benthic organisms depend on the speciation of the contaminant [1]. The level of iron supply to sediments creates contrasting chemical pathways, each producing distinctive mineral assemblag- es. Reliable measurement of Fe redox species (Fe2+ and Fe3+) in sediments is essential for studies of pollutants or trace-element cycling. This is, however, a difficult task, because the distribution of chemical species often changes during sampling and storage. In this work the Diffusive Gradients in Thin-films technique (DGT) is investigated as a passive sampling approach used in combination with photothermal beam deflection spectroscopy (BDS) as a detection method for determination of labile Fe-redox species in sediments and natural waters. DGT offers the advantage of pre-concentration of labile (i.e. bioavailable) Fe species from the total dissolved Fe pool in sediment pore waters [2]. The advantage of using BDS [3-4] is also in avoiding contamination by using additional steps as extraction or pre-concentration. Furthermore, combined DGT-BDS provides 2D information about distribution of Fe2+ and the total Fe content in the resin hydrogels [5]. The goal of this research is to show the repeatability of this technique for determining trace amounts of Fe redox species in environmental samples.
Najdeno v: osebi
Ključne besede: beam deflection spectrometry, diffusive gradients in thin-films, iron species
Objavljeno: 16.07.2019; Ogledov: 1927; Prenosov: 0
.pdf Polno besedilo (29,60 MB)

44.
45.
46.
A multi-thermal-lens approach to evaluation of multi-pass probe beam configuration in thermal lens spectrometry
Humberto Cabrera, Leja Goljat, Dorota Korte, Ernesto Marin, Mladen Franko, izvirni znanstveni članek

Opis: In this work, a recently proposed thermal lens instrument based on multi-pass probe beam concept is investigated and described as a multi-thermal-lens equivalent system. A simulation of the photothermal lens signal formation in a multi-thermal-lens equivalent configuration of the system is performed and validated by comparing the experimental signals of single, dual and ten-pass configurations to theoretically calculated values. The theoretically predicted enhancement of the signal is 9 to 10-fold for a weak thermal lens when comparing the ten-pass configuration with the conventional single-pass thermal lens system. Experimentally achieved signal enhancement in the ten-pass system is 8.3 for pure ethanol sample and between 8 and 9 for solutions with different concentrations of the Fe(II) - 1,10-Phenanthroline complex. Additionally, a value of 9.1 was calculated as the ratio of the slopes of the calibration lines obtained using the ten-pass and single-pass configurations. The achieved limit of detection for determination of Fe(II), in the ten-pass configuration, was 0.4 µgL-1, with a relative standard deviation around 4.5%, which compares favorably with previously reported results for TLS determination of Fe(II) in thin samples using low excitation power. For the multi-pass configuration the linear range of measurement is reduced when compared to the single-pass configuration. This is explained by the theoretical analysis of the photothermal signal under multi-pass condition, which shows the important contribution of the nonlinear term in the theoretical expression for the photothermal signal. The ten-pass configuration, which is presented and validated experimentally for the first time, offers important signal enhancement needed in recently developed TLS instruments with tunable, low power excitation sources.
Najdeno v: osebi
Ključne besede: Thermal lens spectrometry, Photothermal detection, Trace determination, Chemical sensor
Objavljeno: 10.12.2019; Ogledov: 1900; Prenosov: 0
.pdf Polno besedilo (656,75 KB)

47.
Determination of Iron in Environmental Water Samples by FIA-TLS
Mladen Franko, Arne Bratkič, Dorota Korte, Hanna Budasheva, Leja Goljat, Gaja Tomšič, 2019, izvirni znanstveni članek

Opis: The determination of low concentration of iron in natural waters can be difficult due to the complexity of natural water, but primarily because it requires preconcentration of the sample with solvent extraction. In this work we report on results of thermal lens spectrometry (TLS) coupled to flow injection analysis (FIA) as a highly sensitive FIA-TLS method of iron detection. The concentration of iron redox species was determined using 1,10-phenanthroline (PHN), that forms stable complexes with Fe(II) ions which are characterized by an absorption maximum at 508 nm. The TLS system using a 633 nm probe laser and 530 nm pump laser beam was exploited for on-line detection in flow injection analysis, where a PHN solution was used as the carrier solution for FIA. The concentration of the complexing agent affects the quality of the TLS signal, and the optimal concentration was found at 1 mM PHN. The achieved limits of detection (LODs) for Fe(II) and total iron were 33 nM for Fe(II) and 21 nM for total iron concentration. The method was further validated by determining the linear concentration range, specificity in terms of analytical yield and by determining concentration of iron in a water sample from a local water stream.
Najdeno v: osebi
Ključne besede: Flow injection analysis, iron concentration, thermal lens spectroscopy
Objavljeno: 18.12.2019; Ogledov: 1845; Prenosov: 70
.pdf Polno besedilo (690,39 KB)

48.
49.
Implementation of high performance liquid chromatography coupled to thermal lens spectrometry (HPLC‑TLS) for quantification of pyranoanthocyanins during fermentation of Pinot Noir grapes
Lorena Butinar, Jelena Topič Božič, Natka Ćurko, Karin Kovačević Ganić, Branka Mozetič Vodopivec, Dorota Korte, Mladen Franko, 2020, izvirni znanstveni članek

Opis: In this work high performance liquid chromatography coupled to thermal lens spectrometry (HPLC-TLS) was applied for monitoring of vinylphenolic pyranoanthocyanins formation during the fermentation of Pinot Noir wines. Vinylphenolic pyranoanthocyanins are wine pigments, present in low concentrations, but very important for wine colour stability. Fermentation process was conducted with four different yeast strains, used as starters, either in sequential fermentation of non-Saccharomyces with S. cerevisiae yeast or as single fermentation with S. cerevisiae yeasts in order to test the applicability of developed method for monitoring of selected compounds in real wine fermentation experiments. The developed HPLC-TLS method showed higher sensitivity compared to HPLC coupled to diode array detection (DAD) technique for particular wine colour compounds. Obtained limits of detection (LODs), were 6- and 22-times lower in comparison to HPLC–DAD in gradient and isocratic elution mode, respectively, whereas limits of quantification (LOQs) 5 and 18-times lower. Lower LODs enabled earlier observation of vinylphenolic pyranoanthocyanins formation during fermentation (already at day 7) in the case of HPLC-TLS method in gradient mode, while by using HPLC–DAD in gradient elution mode the formation of vinylphenolic pyranoanthocyanins was noticed only after 12 days of fermentation.
Najdeno v: osebi
Ključne besede: Thermal lens spectrometry (TLS), High performance liquid chromatography (HPLC), Pyranoanthocyanins, Wine, Yeasts
Objavljeno: 18.06.2020; Ogledov: 1740; Prenosov: 0
.pdf Polno besedilo (1,94 MB)

50.
Iskanje izvedeno v 0 sek.
Na vrh