Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


61 - 70 / 125
Na začetekNa prejšnjo stran3456789101112Na naslednjo stranNa konec
61.
62.
63.
The detection and study of biologically active compounds in environmental processes and samples
Mojca Žorž Furlan, doktorska disertacija

Opis: Environmental pollution in the 21th century still represents a global problem for human and animal health. Despite general awareness about released substances and their degradation products their fate and possibilities of removal are not well investigated. Even though the chemicals released are dispersed and diluted in water cycles, their poor biodegradability and/or strong accumulation can result in the intoxication of exposed organisms. Similarly, as a part of the environment, food can get contaminated by bioactive substances during different steps of preparation. Not only artificial compounds such as pesticides or pharmaceuticals, but also natural toxins enter the food chain and impact negatively on humans' and animals' health. In addition, the activity of some bacteria can influence the production of amines from amino acids after fermentation, to which the human body responds with several symptoms of intoxication. Several analytical methods for the determination of trace levels of broad range contaminants have been developed. Due to the largely robust, selective and sensitive features of the conventional (rearguard) techniques, they represent the first choice for analysing multiple organic compounds in frequently very complex matrices. However, screening (vanguard) methods are paving the way in the chemical analytics as a solution that provides simplicity and rapid analytical responses with binary (yes/no) answers. They require little or no sample treatment as well as more economically-efficient instrumentation. The combination of vanguard-rearguard analytical strategies hence offers a compromise between classical analytical figures of merit and productivity-related characteristics. In the first part of our research feasibility studies for the application of TLS and/or TLM in novel analytical methods for the determination of lipid-lowering drug atorvastatin and a mycotoxin ochratoxin A . The survey on atorvastatin performed spectrophotometrically has shown a decrease of ATV-sulpho-vanillin product at the wavelength of its maximum absorbance after dilution by organic solvent, which was investigated due to the possible increasing of the method sensitivity. As the predicted LODs that could be obtained by TLM (0.3 mg/L) could not reach the concentration of ATV usually present in the environment (ng/L-g/L) further experiments on this subject were therefore not justified. On the other hand, the ELISA assay for the determination of ochratoxin A was performed. In case of μFIA-TLM, the measurements were influenced by high background signal resulting in high LODs of TLM (470 pg/mL), which is known as a background limited technique. It was estimated that the LODs of standard ELISA assay could not be significantly improved, therefore no further research was conducted in this direction. In the second part of the dissertation, a sensitive rearguard system by coupling HPLC and TLS for the determination of biogenic amines in wine samples was developed. Putrescine, cadaverine, histamine and tyramine were separated and detected on a HPLC-TLS system after derivatization by dabsyl chloride. The method was optimized in terms of chromatographic conditions and in terms of TLS parameters. Also, the sensitivity of the newly developed method was evaluated by comparing the TLS detection with DAD detection in terms of LOD values, where TLS showed 3.6-fold improvement compared to DAD. Afterwards, the standard addition calibration was performed and evaluated for its recoveries (86−117%) in the determination of the four BAs. The applicability of the novel method was tested by the analysis of real white and red wine samples and by comparing the results to the standard HPLC-FL method and concentrations of BAs in wine samples were in good accordance. In addition, the dabsylated BAs showed better stability compared to the OPA derivatives as they have not lost the peak intensity after 17h of storage. In the third part, a vanguard system for detection of the overall biogenic amines concentration was developed by employing μFIA-TLM. Initially, NH4Cl standard solutions were applied in the indophenol reaction for batch mode, off-line μFIA-TLM and in an on-line indophenol formation for μFIA-TLM detection. By adding 50 % of EtOH to indophenol we obtained 9-fold improvement. In addition, indophenol showed good stability under TLM conditions. We optimized the microfluidic and TLM parameters in the off-line and on-line indophenol reaction. The addition of 5% ethanol to the reagent in the on-line reaction resulted in the 3-fold improvement of the signal-to-noise ratio. Further on, the overall reaction, including the enzymatic and the following indophenol reaction, was optimized by choosing the optimal buffer (pH=7, 0.5 M) and alkaline conditions (2M NaOH). The influence of interferences from amino compounds was also evaluated and discussed. The off-line and on-line μFIA-TLM were evaluated by their performance characteristics. The LOD for ammonia detection reached 2.3 μM and the applicability in ammonia detection in water samples was discussed. Similar LOD of 3.2 μM was obtained for the overall concentration of BAs and LOD of 3.8 μM for histamine, which is more than 4-folds lower value as the lowest suggested limits of intake for histamine in wine samples (2 mg/L; 18 μM). Finally, an immobilization procedure on magnetic nanoparticles was developed for the possible implementation of the selected enzyme in a miniaturized biosensor.
Ključne besede: thermal lens spectrometry, thermal lens microscopy, high performance liquid chromatography, microfluidics, biogenic amines, microbial transglutaminase, indophenol (Berthelot) reaction
Objavljeno v RUNG: 04.06.2018; Ogledov: 4839; Prenosov: 247
.pdf Celotno besedilo (2,90 MB)
Gradivo ima več datotek! Več...

64.
Hemichrome Determination by Thermal Lensing with Polyethylene Glycols for Signal Enhancement in Aqueous Solutions
Viktoriya Galimova, Mladen Franko, Mikhail Proskurnin, Mingqiang Liu, 2018, izvirni znanstveni članek

Opis: The thermal lens technique is proposed for the determination of total hemoglobin in the form of reversible hemichrome. The conditions were optimized (concentration of sodium dodecyl sulfate, 2 mM) to attain the maximum sensitivity with the use of polyethylene glycols as signal enhancers. For polyethylene glycols with molecular weights 1500–35000 Da in a concentration range of 5–15% w/w (5–25 mM), the influence on thermal lens signal enhancement was estimated. It is shown that the use of 5% w/w polyethylene glycol 2000 provides the maximum increase in the thermal lens enhancement factor (by 40%) in comparison with unmodified aqueous solutions. The detection limit of iron(II) tris(1,10-phenanthrolinate) as a model system is 60 nM. Under these conditions, the thermal lens detection limit of hemichrome is 10 nM, which shows a 15-fold enhancement compared to spectro- photometry. Modification of the medium with polyethylene glycols decreases the limit of detection of hemichrome determination by 15% in comparison with unmodified aqueous solutions due to better reproducibility for the range of concentrations from 0.02 to 0.9 μM.
Ključne besede: Hemoglobin, hemikrom, optotermična spektroskopija, etilenglikol, spektrometrija s toplotnimi lečami
Objavljeno v RUNG: 16.04.2018; Ogledov: 4029; Prenosov: 0
Gradivo ima več datotek! Več...

65.
66.
Trace Detection and Photothermal Spectral Characterization by a Tuneable Thermal Lens Spectrometer with White-Light Excitation
Humberto Cabrera, Dorota Korte, Mladen Franko, 2018, izvirni znanstveni članek

Opis: In the thermal lens experimental set-up we replaced the commonly employed pump laser by a halogen lamp, combined with an interference lter, providing a tuneable, nearly monochromatic pump source over the range of wavelengths 430–710 nm. Counter-propagating pump and probe beams are used and a 1 mm path-length sam- ple cell together with the interference lter makes an optical cavity, providing ampli cation of the thermal lens signal, which leads to enhancement of the measurement sensitivity, and enables detection of absorbances on the order of 5×10− 6. Ampli ed thermal lens signal allows us to replace the typical lock-in ampli er and digital os- cilloscope with a silicon photodetector, Arduino board, and a personal computer, offering the possibility for a compact, robust and portable device, useful for in- eld absorption measurements in low concentration or weakly absorbing species. The use of a white light source for optical pumping, an interference lter for wavelength selection and direct diagnostic of the thermal lens signal increase the versatility of the instrument and simpli- es substantially the experimental setup. Determination of Fe(II) concentrations at parts per billion levels was performed by the described white-light thermal lens spectrophotometer and the absorption spectrum for 50μg/ L Fe(II)-1,10-phenanthroline was well reproduced with an average measurement precision of 4%. The obtained limits of detection and quantitation of Fe(II) determination at 510nm are 3μgL− 1 and 11μgL− 1, respectively. The calibration curve was linear in the concentration range of LOQ-500μgL− 1 with reproducibility between 2% and 6%, con rming that this instrument provides good spectrometric capabilities such as high sensitivity, tune- ability and good reproducibility. In addition, the versatility of the instrument was demonstrated by recording the photothermal spectrum of gold nanostructured material and determination of excitation wavelength with most ef cient optical to thermal energy conversion, which differs considerably (cca 100 nm) from the absorption maximum of the investigated sample.
Ključne besede: thermal lens spectrometry, Fe(II) determination, photothermal technique, multi-wavelength excitation
Objavljeno v RUNG: 21.02.2018; Ogledov: 4032; Prenosov: 0
Gradivo ima več datotek! Več...

67.
68.
NOVEL APPROACHES FOR THE DETERMINATION OF BIOGENIC AMINES IN FOOD SAMPLES
Mladen Franko, Mojca Žorž, Mitja Martelanc, Sara Budal, 2017, izvirni znanstveni članek

Opis: In this work, new analytical approaches for determination of biogenic amines in wines were developed. For the first time, we studied the derivatization of BAs in wines with naphthalene- 2,3-dicarboxaldehyde (NDA) and with dabsyl chloride (DBS) and analysis of derivatized BAs by HPLC coupled to fluorescence (HPLC-NDA-FL) and thermal lens spectrometry (HPLC-DBS-TLS) detectors. The sensitivity of the two methods (LODs HPLC-NDA-FL in the range 27-73 μg/L; LODs HPLC-DBS-TLS in the range 3.4-11 μg/L) was higher than that of the official method for biogenic amines in wines, OIV-MA-AS315-18 (60-77 μg/L). For its best performances, the HPLC-DBS-TLS technique was applied to the analysis of putrescine, cadaverine, histamine and tyramine in two white wine samples. Additionally, exploiting the Berthelot reaction, the TLS fast screening of biogenic amines in wines, following the release of ammonia by transglutaminase, was also proposed. This approach allowed us to determine total biogenic amount content in concentrations below 0.1 mg/L, expressed as equivalents of histamine.
Ključne besede: biogenic amines, NDA, liquid chromatography, TLS, fluorescence, wine
Objavljeno v RUNG: 02.11.2017; Ogledov: 4384; Prenosov: 269
.pdf Celotno besedilo (441,06 KB)

69.
Facile synthesis, structure, biocompatibility and antimicrobial property of gold nanoparticle composites from cellulose and keratin
Chieu D. Tran, Franja Prosenc, Mladen Franko, 2018, izvirni znanstveni članek

Opis: A novel, one-pot method was developed to synthesize gold nanoparticle composite from cellulose (CEL), wool keratin (KER) and chloroauric acid. Two ionic liquids, butylmethylimmidazolium chloride and ethylmethylimmidazolium bis(trifluoromethylsulfonyl)imide were used to dissolve CEL, KER and HAuCl4. X-ray diffraction and X-ray photoelectron results show that Au3+ was completely reduced to Au0NPs with size of (5.5 ± 1) nm directly in the composite with NaBH4. Spectroscopy and imaging results indicate that CEL and KER remained chemically intact and were homogeneously distributed in the com- posites with Au0NPs. Encapsulating Au0NPs into [CEL+KER] composite made the composite fully biocom- patible and their bactericidal capabilities were increased by the antibacterial activity of Au0NPs. Specifically, the [CEL+KER+Au0NPs] composite exhibited up to 97% and 98% reduction in growth of antibi- otic resistant bacteria such as vancomycin resistant Enterococcus faecalis and methicillin resistant Staphylococcus aureus, and was not cytotoxic to human fibroblasts. While [CEL+KER] composite is known to possess some antibacterial activity, the enhanced antibacterial observed here was due solely to added Au0NPs. These results together with our previous finding that [CEL+KER] composites can be used for con- trolled delivery of drugs clearly indicate that the [CEL+KER+Au0NPs] composites possess all required properties for successful use as dressing to treat chronic ulcerous infected wounds.
Ključne besede: Ionic liquid Green Sustainable Polysaccharide Keratin Wound dressing Gold nanoparticles Antibiotic-resistant bacteria
Objavljeno v RUNG: 27.09.2017; Ogledov: 4316; Prenosov: 0
Gradivo ima več datotek! Več...

70.
Iskanje izvedeno v 0.07 sek.
Na vrh