Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 3 / 3
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Recommendations for reporting equivalent black carbon (eBC) mass concentrations based on long-term pan-European in-situ observations
Marjan Savadkoohi, Marco Pandolfi, Olivier Favez, Jean-Philippe Putaud, Konstantinos Eleftheriadis, Markus Fiebig, Philip Hopke, Paolo Laj, A. Wiedensohler, Griša Močnik, 2024, izvirni znanstveni članek

Opis: A reliable determination of equivalent black carbon (eBC) mass concentrations derived from filter absorption photometers (FAPs) measurements depends on the appropriate quantification of the mass absorption cross-section (MAC) for converting the absorption coefficient (babs) to eBC. This study investigates the spatial–temporal variability of the MAC obtained from simultaneous elemental carbon (EC) and babs measurements performed at 22 sites. We compared different methodologies for retrieving eBC integrating different options for calculating MAC including: locally derived, median value calculated from 22 sites, and site-specific rolling regression MAC. The eBC concentrations that underwent correction using these methods were identified as LeBC (local MAC), MeBC (median MAC), and ReBC (Rolling MAC) respectively. Pronounced differences (up to more than 50 %) were observed between eBC as directly provided by FAPs (NeBC; Nominal instrumental MAC) and ReBC due to the differences observed between the experimental and nominal MAC values. The median MAC was 7.8 ± 3.4 m2/g from 12 aethalometers at 880 nm, and 10.6 ± 4.7 m2/g from 10 MAAPs at 637 nm. The experimental MAC showed significant site and seasonal dependencies, with heterogeneous patterns between summer and winter in different regions. In addition, long-term trend analysis revealed statistically significant (s.s.) decreasing trends in EC. Interestingly, we showed that the corresponding corrected eBC trends are not independent of the way eBC is calculated due to the variability of MAC. NeBC and EC decreasing trends were consistent at sites with no significant trend in experimental MAC. Conversely, where MAC showed s.s. trend, the NeBC and EC trends were not consistent while ReBC concentration followed the same pattern as EC. These results underscore the importance of accounting for MAC variations when deriving eBC measurements from FAPs and emphasizes the necessity of incorporating EC observations to constrain the uncertainty associated with eBC.
Ključne besede: equivalent black carbon, mass absorption cross-section, filter absorption photometers, elemental carbon, absorption, site specific MAC, rolling MAC
Objavljeno v RUNG: 04.03.2024; Ogledov: 264; Prenosov: 3
.pdf Celotno besedilo (2,46 MB)
Gradivo ima več datotek! Več...

2.
3.
Elucidating local pollution and site representativeness at the Jungfraujoch, Switzerland through parallel aerosol measurements at an adjacent mountain ridge
Nicolas Bukowiecki, Benjamin Brem, Günther Wehrle, Griša Močnik, Stéphane Affolter, Markus Christian Leuenberger, Martine Collaud Coen, Maxime Hervo, Urs Baltensperger, Martin Gysel, 2021, izvirni znanstveni članek

Opis: Many long-term air pollution and climate monitoring stations face the issue of increasing anthropogenic activities in their vicinity. Furthermore, the spatial representativeness of the sites is often not entirely understood especially in mountainous terrain with complex topographic features. This study presents a 5-year comparison of parallel aerosol measurements (total particle number concentration and equivalent black carbon mass concentration) at the Jungfraujoch in the Swiss Alps (JFJ, 3580 m a.s.l.), and an adjacent mountain ridge, the Jungfrau East Ridge (JER, 3705 m a.s.l.), in 1000 m air-line distance to the main site. The parallel aerosol measurements reveal characteristic differences in the diurnal variations between the two sites under certain specific meteorological conditions. Our analysis estimates that on 20-40% of the days local activities at the Jungfraujoch have a clear influence on the measured time series of the total aerosol number concentration and the equivalent black carbon mass concentration. This influence is mainly seen in form of strong isolated spikes rather than by an increase in the on-site background concentration. They can thus be flagged during the data quality assurance process and filtered from those measurement parameters available at high time resolution. Removing the spikes from the original time series results in daily mean values for the total aerosol number concentration and equivalent black carbon mass concentration that are 5-10 % lower compared to the original signals. During nighttime with hardly any local pollution sources that cause spikes this percentage decreases towards 0%. The signal baselines at the Jungfraujoch and Jungfrau East Ridge correlate well during more than 50% of the days.
Ključne besede: aerosol long-term monitoring, equivalent black carbon, aerosol number concentration, spatial variation
Objavljeno v RUNG: 15.03.2021; Ogledov: 1906; Prenosov: 71
URL Povezava na celotno besedilo
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.02 sek.
Na vrh