Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 2 / 2
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Sequence disorder-induced first order phase transition in confined polyelectrolytes
V. Stepanyan, Artem Badasyan, V. Morozov, Yevgeni S. Mamasakhlisov, Rudolf Podgornik, 2024, izvirni znanstveni članek

Opis: We consider a statistical mechanical model of a generic flexible polyelectrolyte, comprised of identically charged monomers with long-range electrostatic interactions and short-range interactions quantified by a disorder field along the polymer contour sequence, which is randomly quenched. The free energy and the monomer density profile of the system for no electrolyte screening are calculated in the case of a system composed of two infinite planar bounding surfaces with an intervening oppositely charged polyelectrolyte chain. We show that the effect of the contour sequence disorder, mediated by short-range interactions, leads to an enhanced localization of the polyelectrolyte chain and a first order phase transition at a critical value of the inter-surface spacing. This phase transition results in an abrupt change of the pressure from negative to positive values, effectively eliminating polyelectrolyte mediated bridging attraction.
Ključne besede: polyelectrolyte, Anderson localization, Poisson-Boltzmann equation, phase transitions, electrostatics, polyelectrolytes, Edwards equation, nonlinear schrodinger equation, nucleic acids
Objavljeno v RUNG: 04.10.2024; Ogledov: 619; Prenosov: 2
URL Povezava na datoteko
Gradivo ima več datotek! Več...

2.
Detection of urea in artificial urine using capacitive field-effect biosensors modified with a stacked polyelectrolyte-enzyme bilayer
A. Tsokolakyan, Artem Badasyan, 2024, objavljeni povzetek znanstvenega prispevka na konferenci

Opis: Capacitive field-effect biosensors modified with a stacked polyelectrolyte/enzyme urease bilayer were applied for the detection of the urinary biomarker urea in phosphate buffer and artificial urine. A theoretical kinetic model of the biosensor was developed and compared with the experimentally observed results.
Ključne besede: field-effect sensors, urea biosensors, polyelectrolyte, urease, artificial urine
Objavljeno v RUNG: 02.10.2024; Ogledov: 568; Prenosov: 2
URL Povezava na datoteko
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.01 sek.
Na vrh