1.
Real-time multi-marker measurement of organic compounds in human breath: Towards fingerprinting breath
Iain R. White, Kerry A Willis, Christopher Whyte, Rebecca Cordell, Robert S Blake, Andrew J Wardlaw, 2013, original scientific article

Abstract: The prospects for exploiting proton transfer reaction-time of flight-mass spectrometry (PTR-ToF-MS) in medical diagnostics are illustrated through a series of case studies. Measurements of acetone levels in the breath of 68 healthy people are presented along with a longitudinal study of a single person over a period of 1 month. The median acetone concentration across the population was 484 ppbV with a geometric standard deviation (GSD) of 1.6, whilst the average GSD during the single subject longtitudinal study was 1.5. An additional case study is presented which highlights the potential of PTR-ToF-MS in pharmacokinetic studies, based upon the analysis of online breath samples of a person following the consumption of ethanol. PTR-ToF-MS comes into its own when information across a wide mass range is required, particularly when such information must be gathered in a short time during a breathing cycle. To illustrate this property, multicomponent breath analysis in a small study of cystic fibrosis patients is detailed, which provides tentative evidence that online PTR-ToF-MS analysis of tidal breath can distinguish between active infection and non-infected patients.
Keywords: Volatile Organic Compounds, breath, proton transfer reaction mass spectrometry, Cystic Fibrosis
Published in RUNG: 22.07.2019; Views: 3228; Downloads: 0
This document has many files! More...

2.
Increased sensitivity in proton transfer reaction mass spectrometry by incorporation of a radio frequency ion funnel
Shane Barber, Robert S Blake, Iain R. White, Paul S Monks, Fraser Reich, Stephen Mullock, Andrew M Ellis, 2012, original scientific article

Abstract: A drift tube capable of simultaneously functioning as an ion funnel is demonstrated in proton transfer reaction mass spectrometry (PTR-MS) for the first time. The ion funnel enables a much higher proportion of ions to exit the drift tube and enter the mass spectrometer than would otherwise be the case. An increase in the detection sensitivity for volatile organic compounds of between 1 and 2 orders of magnitude is delivered, as demonstrated using several compounds. Other aspects of analytical performance explored in this study include the effective E/N (ratio of electric field to number density of the gas) and dynamic range over which the drift tube is operated. The dual-purpose drift tube/ion funnel can be coupled to various types of mass spectrometers to increase the detection sensitivity and may therefore offer considerable benefits in PTR-MS work.
Keywords: Analytical performance, Detection sensitivity, Drift tube, Dynamic range, Ion funnels, Proton-transfer reaction mass spectrometry, Volatile organic compounds
Published in RUNG: 18.07.2019; Views: 2779; Downloads: 0