Naslov:Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients–comparison of two sampling methods
Avtorji:ID White, Iain R., Laboratory for Environmental and Life Sciences, University of Nova Gorica, Nova Gorica, Slovenia (Avtor)
ID Oort, Pouline M. van, Department of Intensive Care, Amsterdam UMC – location Academic Medical Centre (AMC), Amsterdam, the Netherlands (Avtor)
ID Ahmed, Waqar, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK (Avtor)
ID Johnson, Craig, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK (Avtor)
ID Bannard-Smith, Jonathan, Manchester Academic Health Science Centre, Manchester University Hospitals NHS Foundation Trust, Manchester, UK. (Avtor)
ID Felton, Timothy, Manchester Academic Health Science Centre, Manchester University Hospitals NHS Foundation Trust, Manchester, UK (Avtor)
ID Bos, Lieuwe D., Department of Intensive Care, Amsterdam UMC – location Academic Medical Centre (AMC), Amsterdam, the Netherlands (Avtor)
ID Goodacre, Royston, Department of Biochemistry, Institute of Integrative Biology, University of Liverpool, UK (Avtor)
ID Dark, Paul, Manchester Academic Health Science Centre, Manchester University Hospitals NHS Foundation Trust, Manchester, UK (Avtor)
ID Fowler, Stephen J., Manchester Academic Health Science Centre, Manchester University Hospitals NHS Foundation Trust, Manchester, UK (Avtor)
Datoteke: Gradivo nima datotek, ki so prostodostopne za javnost. Gradivo je morda fizično dosegljivo v knjižnici fakultete, zalogo lahko preverite v COBISS-u. Povezava se odpre v novem oknu
Jezik:Angleški jezik
Vrsta gradiva:Delo ni kategorizirano
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:UNG - Univerza v Novi Gorici
Opis:Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in “real life” in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure–volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of data analysed above the MDL. The relative performance of the two methods differed depending on the VOC under study and both methods showed sensitivity towards different exhaled VOCs. Furthermore, method performance differed depending on recruitment site, as the centres were equipped with different brands of respiratory equipment, an important consideration for the design of multicentre studies investigating exhaled VOCs in mechanically ventilated patients.
Ključne besede:Volatile organic compounds, infection, breath, ventilator associated pneumonia
Leto izida:2020
Št. strani:10
Številčenje:online
PID:20.500.12556/RUNG-5987 Novo okno
COBISS.SI-ID:42126339 Novo okno
DOI:DOI: 10.1039/c9an01134j Novo okno
NUK URN:URN:SI:UNG:REP:30UP2PTT
Datum objave v RUNG:10.12.2020
Število ogledov:2472
Število prenosov:0
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Analyst
Založnik:Royal society of Chemistry
Leto izida:2020
ISSN:1364-5528

Nazaj