Naslov: | Development of prototype of electronic speckle interferometry based spirometer |
---|
Avtorji: | ID Swapna, Mohanachandran Nair Sindhu, UNIVERSITY OF KERALA (Avtor) ID ARUN, KUMAR, UNIVERSITY OF KERALA (Avtor) ID SUNIL, KUMAR, UNIVERSITY OF KERALA (Avtor) ID S, SREEJYOTHI, UNIVERSITY OF KERALA (Avtor) ID VIMAL, RAJ, UNIVERSITY OF KERALA (Avtor) ID SANKARANARAYANA IYER, SANKARARAMAN (Avtor) |
Datoteke: |
Gradivo nima datotek, ki so prostodostopne za javnost. Gradivo je morda fizično dosegljivo v knjižnici fakultete, zalogo lahko preverite v COBISS-u. |
---|
Jezik: | Angleški jezik |
---|
Vrsta gradiva: | Delo ni kategorizirano |
---|
Tipologija: | 1.01 - Izvirni znanstveni članek |
---|
Organizacija: | UNG - Univerza v Novi Gorici
|
---|
Opis: | The paper reports the design, construction, and calibration of the prototype of a spirometer based on electronic
speckle interferometry (ESPI). The conventional ESPI setup is modified by incorporating a DNM (Diaphragm-Nozzle-Mouthpiece) module comprising a metallic diaphragm, regulated airflow channel, and a mouthpiece. The
exhaled air after a deep breathe is channelled to the DNM module where the diaphragm gets deformed. From the
circular fringe pattern obtained by subtracting the speckled images before and after deformation of the metallic
diaphragm, the radius of curvature (R) due to deformation is calculated using the principle of Newton’s rings.
The value of R and peak expiratory flow rate (PEFR) from the standard spirometer reading are correlated. From
the 640 observations spread over the range 100 - 500 L/min in the standard spirometer, an empirical relation
is set in terms of R from the scatter plot. The ESPI spirometer (ESPIS) is validated by determining the value of
R corresponding to a particular PEFR from the empirical relation and also from the standard spirometer. The
PEFR calculated from ESPIS matches well with the standard spirometer reading, which suggests that the system
designed and constructed can be used for biomedical applications for assessing lungs’ efficiency. |
---|
Ključne besede: | Speckle, Spirometer, DNM module, ESPIS, Peak expiratory flow rate |
---|
Verzija publikacije: | Objavljena publikacija |
---|
Leto izida: | 2021 |
---|
Št. strani: | 6 |
---|
Številčenje: | 1, 136 |
---|
PID: | 20.500.12556/RUNG-7394 |
---|
COBISS.SI-ID: | 112986883 |
---|
DOI: | 10.1016/j.optlaseng.2020.106318 |
---|
NUK URN: | URN:SI:UNG:REP:JFMQEBKQ |
---|
Datum objave v RUNG: | 28.06.2022 |
---|
Število ogledov: | 2067 |
---|
Število prenosov: | 0 |
---|
Metapodatki: | |
---|
:
|
Kopiraj citat |
---|
| | | Skupna ocena: | (0 glasov) |
---|
Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
---|
Objavi na: | |
---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |