Repozitorij Univerze v Novi Gorici

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:A novel tool for the absolute end-to-end calibration of fluorescence telescopes : the XY-scanner
Avtorji:ID Schäfer, Christoph (Avtor)
ID Filipčič, Andrej (Avtor)
ID Lundquist, Jon Paul (Avtor)
ID Shivashankara, Shima Ujjani (Avtor)
ID Stanič, Samo (Avtor)
ID Vorobiov, Serguei (Avtor)
ID Zavrtanik, Danilo (Avtor)
ID Zavrtanik, Marko (Avtor), et al.
Datoteke:.pdf ICRC2023_305.pdf (5,33 MB)
MD5: 661DAA461E58350C980DE78ED207874A
 
URL https://pos.sissa.it/444/
 
URL https://pos.sissa.it/444/305/pdf
 
Jezik:Angleški jezik
Vrsta gradiva:Neznano
Tipologija:1.08 - Objavljeni znanstveni prispevek na konferenci
Organizacija:UNG - Univerza v Novi Gorici
Opis:The Pierre Auger Observatory uses 27 large-aperture wide-angle Schmidt telescopes to measure the longitudinal profile of air showers using the air-fluorescence technique. Up to the year 2013, the absolute calibration of the telescopes was performed by mounting a uniform large-diameter light source on each of the telescopes and illuminating the entire aperture with a known photon flux. Due to the high amount of work and person-power required, this procedure was only carried out roughly once every three years, and a relative calibration was performed every night to track short-term changes. Since 2013, only the relative calibration has been performed. In this paper, we present a novel tool for the absolute end-to-end calibration of the fluorescence detectors, the XY-Scanner. The XY-Scanner uses a portable integrating sphere as a light source, which has been absolutely calibrated. This light source is installed onto a motorized rail system and moved across the aperture of each telescope. We mimic the illumination of the entire aperture by flashing the light source at ∼1700 positions evenly distributed across the telescope aperture. For the absolute calibration of the light source, we built a dedicated setup that uses a NIST-calibrated photodiode to measure the average photon flux and a PMT to track the pulse-to-pulse stability. We present the laboratory setups used to study the characteristics of the employed light sources and discuss the inter-calibration between selected telescopes.
Ključne besede:ultra-high energy cosmic rays, Pierre Auger Observatory, fluorescence detectors, longitudinal profile
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.01.2023
Leto izida:2023
Št. strani:str. 1-13
PID:20.500.12556/RUNG-8790 Novo okno
COBISS.SI-ID:182067459 Novo okno
UDK:52
ISSN pri članku:1824-8039
DOI:10.22323/1.444.0305 Novo okno
NUK URN:URN:SI:UNG:REP:DIN3LQPC
Datum objave v RUNG:23.01.2024
Število ogledov:461
Število prenosov:6
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del zbornika

Naslov:38th International Cosmic Ray Conference [also] ICRC2023
COBISS.SI-ID:162195971 Novo okno

Gradivo je del revije

Naslov:Proceedings of science
Skrajšan naslov:Pos proc. sci.
Založnik:Sissa
ISSN:1824-8039
COBISS.SI-ID:20239655 Novo okno

Gradivo je financirano iz projekta

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0031
Naslov:Večglasniška astrofizika

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.

Nazaj