Repozitorij Univerze v Novi Gorici

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po
* po starem in bolonjskem študiju

Opcije:
  Ponastavi


1 - 10 / 41
Na začetekNa prejšnjo stran12345Na naslednjo stranNa konec
1.
Emission of volatile organic compounds from residential biomass burning and their rapid chemical transformations
Maximillien Desservettaz, Michael Pikridas, Iasonas Stavroulas, Aikaterini Bougiatioti, Eleni Liakakou, Nikolaos Hatzianastassiou, Jean Sciare, Nikolaos Mihalopoulos, Efstratios Bourtsoukidis, 2023, izvirni znanstveni članek

Opis: Biomass combustion releases a complex array of Volatile Organic Compounds (VOCs) that pose significant challenges to air quality and human health. Although biomass burning has been extensively studied at ecosystem levels, understanding the atmospheric transformation and impact on air quality of emissions in urban environments remains challenging due to complex sources and burning materials. In this study, we investigate the VOC emission rates and atmospheric chemical processing of predominantly wood burning emissions in a small urban centre in Greece. Ioannina is situated in a valley within the Dinaric Alps and experiences intense atmospheric pollution accumulation during winter due to its topography and high wood burning activity. During pollution event days, the ambient mixing ratios of key VOC species were found to be similar to those reported for major urban centres worldwide. Positive matrix factorisation (PMF) analysis revealed that biomass burning was the dominant emission source (>50 %), representing two thirds of OH reactivity, which indicates a highly reactive atmospheric mixture. Calculated OH reactivity ranges from 5 s−1 to an unprecedented 278 s−1, and averages at 93 ± 66 s−1 at 9 PM, indicating the presence of exceptionally reactive VOCs. The highly pronounced photochemical formation of organic acids coincided with the formation of ozone, highlighting the significance of secondary formation of pollutants in poorly ventilated urban areas. Our findings underscore the pressing need to transition from wood burning to environmentally friendly sources of energy in poorly ventilated urban areas, in order to improve air quality and safeguard public health.
Ključne besede: biomass burning, urban air quality, VOCs, emission factors, source apportionment
Objavljeno v RUNG: 13.05.2024; Ogledov: 130; Prenosov: 1
.pdf Celotno besedilo (8,93 MB)

2.
Field evaluation of low-cost PM sensors (Purple Air PA-II) under variable urban air quality conditions, in Greece
Iasonas Stavroulas, Georgios Grivas, Panagiotis Michalopoulos, Eleni Liakakou, Aikaterini Bougiatioti, Panayiotis Kalkavouras, Kyriaki Maria Fameli, Nikolaos Hatzianastassiou, Nikolaos Mihalopoulos, Evangelos Gerasopoulos, 2020, izvirni znanstveni članek

Opis: Recent advances in particle sensor technologies have led to an increased development and utilization of low-cost, compact, particulate matter (PM) monitors. These devices can be deployed in dense monitoring networks, enabling an improved characterization of the spatiotemporal variability in ambient levels and exposure. However, the reliability of their measurements is an important prerequisite, necessitating rigorous performance evaluation and calibration in comparison to reference-grade instrumentation. In this study, field evaluation of Purple Air PA-II devices (low-cost PM sensors) is performed in two urban environments and across three seasons in Greece, in comparison to different types of reference instruments. Measurements were conducted in Athens (the largest city in Greece with nearly four-million inhabitants) for five months spanning over the summer of 2019 and winter/spring of 2020 and in Ioannina, a medium-sized city in northwestern Greece (100,000 inhabitants) during winter/spring 2019–2020. The PM2.5 sensor output correlates strongly with reference measurements (R2 = 0.87 against a beta attenuation monitor and R2 = 0.98 against an optical reference-grade monitor). Deviations in the sensor-reference agreement are identified as mainly related to elevated coarse particle concentrations and high ambient relative humidity. Simple and multiple regression models are tested to compensate for these biases, drastically improving the sensor’s response. Large decreases in sensor error are observed after implementation of models, leading to mean absolute percentage errors of 0.18 and 0.12 for the Athens and Ioannina datasets, respectively. Overall, a quality-controlled and robustly evaluated low-cost network can be an integral component for air quality monitoring in a smart city. Case studies are presented along this line, where a network of PA-II devices is used to monitor the air quality deterioration during a peri-urban forest fire event affecting the area of Athens and during extreme wintertime smog events in Ioannina, related to wood burning for residential heating.
Ključne besede: particulate matter, PM2.5, air quality, low-cost sensors, optical particle counter
Objavljeno v RUNG: 10.05.2024; Ogledov: 122; Prenosov: 3
URL Povezava na datoteko
Gradivo ima več datotek! Več...

3.
4.
5.
Protein quality assessment: why & how
Ario De Marco, 2023, prispevek na konferenci brez natisa

Ključne besede: recombinant protein, protein quality control, protein aggregates
Objavljeno v RUNG: 02.11.2023; Ogledov: 838; Prenosov: 0
Gradivo ima več datotek! Več...

6.
7.
8.
Protein quality control for improved data reproducibility and reliability
Kim Remans, Ario De Marco, Nick Berrow, Mario Lebendiker, Maria Garcia-Alai, Stefan Knauer, Andre Matagne, Anne Perret, Stephan Uebel, Bertrand Raynal, 2022, objavljeni povzetek znanstvenega prispevka na konferenci

Ključne besede: protein quality, evaluation assays, biophysical methods
Objavljeno v RUNG: 13.04.2023; Ogledov: 910; Prenosov: 0
Gradivo ima več datotek! Več...

9.
10.
Iskanje izvedeno v 0.05 sek.
Na vrh