Naslov: | Development and Validation of a High- Performance Liquid Chromatography– Tandem Mass Spectrometry Method for the Simultaneous Determination of Irinotecan and Its Main Metabolites in Human Plasma and Its Application in a Clinical Pharmacokinetic Study |
---|
Avtorji: | ID Posocco, Bianca, CRO, National Cancer Institute, Aviano (PN), Italy (Avtor) ID Mazzega, Elisa, CRO, National Cancer Institute, Aviano (PN), Italy (Avtor) ID Marangon, Elena, CRO, National Cancer Institute, Aviano (PN), Italy (Avtor) ID Toffoli, Giuseppe, CRO, National Cancer Institute, Aviano (PN), Italy (Avtor) |
Datoteke: |
Gradivo nima datotek, ki so prostodostopne za javnost. Gradivo je morda fizično dosegljivo v knjižnici fakultete, zalogo lahko preverite v COBISS-u. |
---|
Jezik: | Angleški jezik |
---|
Vrsta gradiva: | Delo ni kategorizirano |
---|
Tipologija: | 1.01 - Izvirni znanstveni članek |
---|
Organizacija: | UNG - Univerza v Novi Gorici
|
---|
Opis: | Irinotecan is currently used in several cancer regimens mainly in colorectal cancer (CRC). This drug has a narrow therapeutic range and treatment can lead to side effects, mainly neutropenia and diarrhea, frequently requiring discontinuing or lowering the drug dose. A wide inter-individual variability in irinotecan pharmacokinetic parameters and pharmacodynamics has been reported and associated to patients’ genetic background. In particular, a polymorphism in the UGT1A1 gene (UGT1A1*28) has been linked to an impaired detoxification of SN-38 (irinotecan active metabolite) to SN-38 glucuronide (SN-38G) leading to increased toxicities. Therefore, therapeutic drug monitoring of irinotecan, SN-38 and SN-38G is recommended to personalize therapy. In order to quantify simultaneously irinotecan and its main metabolites in patients’ plasma, we developed and validated a new, sensitive and specific HPLC–MS/MS method applicable to all irinotecan dosages used in clinic. This method required a small plasma volume, addition of camptothecin as internal standard and simple protein precipitation. Chromatographic separation was done on a Gemini C18 column (3 μM, 100 mm x 2.0 mm) using 0.1% acetic acid/bidistilled water and 0.1% acetic acid/acetonitrile as mobile phases. The mass spectrometer worked with electrospray ionization in positive ion mode and selected reaction monitoring. The standard curves were linear (R20.9962) over the concentration ranges (10–10000 ng/mL for irinotecan, 1–500 ng/mL for SN-38 and SN-38G and 1–5000 ng/mL for APC) and had good back-calculated accuracy and precision. The intra- and inter-day precision and accuracy, determined on three quality control levels for all the analytes, were always <12.3% and between 89.4% and 113.0%, respectively. Moreover, we evaluated this bioanalytical method by re-analysis of incurred samples as an additional measure of assay reproducibility. This method wassuccessfully applied to a pharmacokinetic study in metastatic CRC patients enrolled in a genotype-guided phase Ib study of irinotecan administered in combination with 5-fluorouracil/ leucovorin and bevacizumab. |
---|
Ključne besede: | Pharmacokinetic, pharmacodynamics, phase I clinical study, colorectal cancer, Mass spectrometry, pharmacogenetics |
---|
Verzija publikacije: | Objavljena publikacija |
---|
Leto izida: | 2015 |
---|
Št. strani: | 18 |
---|
Številčenje: | February 17 |
---|
PID: | 20.500.12556/RUNG-3026-8a0d3099-ce90-a6b4-39f0-2acc94b793fc |
---|
COBISS.SI-ID: | 4724219 |
---|
DOI: | DOI:10.1371/journal.pone.0118194 |
---|
NUK URN: | URN:SI:UNG:REP:QU7X8ELA |
---|
Datum objave v RUNG: | 21.03.2017 |
---|
Število ogledov: | 5462 |
---|
Število prenosov: | 0 |
---|
Metapodatki: | |
---|
:
|
Kopiraj citat |
---|
| | | Skupna ocena: | (0 glasov) |
---|
Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
---|
Objavi na: | |
---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |