Repozitorij Univerze v Novi Gorici

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Intercomparison and characterization of 23 Aethalometers under laboratory and ambient air conditions: : procedures and unit-to-unit variabilities
Avtorji:ID Cuesta-Mosquera, Andrea (Avtor)
ID Močnik, Griša (Avtor)
ID Drinovec, Luka (Avtor)
ID Müller, Thomas (Avtor)
ID Pfeifer, Sascha (Avtor)
ID Cruz Minguillon, Maria (Avtor)
ID Briel, Björn (Avtor)
ID Buckley, Paul (Avtor)
ID Dudoitis, Vadimas (Avtor)
ID Fernández-García, Javier (Avtor), et al.
Datoteke: Gradivo nima datotek, ki so prostodostopne za javnost. Gradivo je morda fizično dosegljivo v knjižnici fakultete, zalogo lahko preverite v COBISS-u. Povezava se odpre v novem oknu
Jezik:Angleški jezik
Vrsta gradiva:Neznano
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:UNG - Univerza v Novi Gorici
Opis:Aerosolized black carbon is monitored worldwide to quantify its impact on air quality and climate. Given its importance, measurements of black carbon mass concentrations must be conducted with instruments operating in quality-checked and ensured conditions to generate data which are reliable and comparable temporally and geographically. In this study, we report the results from the largest characterization and intercomparison of filter-based absorption photometers, the Aethalometer model AE33, belonging to several European monitoring networks. Under controlled laboratory conditions, a total of 23 instruments measured mass concentrations of black carbon from three well-characterized aerosol sources: synthetic soot, nigrosin particles, and ambient air from the urban background of Leipzig, Germany. The objective was to investigate the individual performance of the instruments and their comparability; we analyzed the response of the instruments to the different aerosol sources and the impact caused by the use of obsolete filter materials and the application of maintenance activities. Differences in the instrument-to-instrument variabilities from equivalent black carbon (eBC) concentrations reported at 880 nm were determined before maintenance activities (for soot measurements, average deviation from total least square regression was −2.0 % and the range −16 % to 7 %; for nigrosin measurements, average deviation was 0.4 % and the range −15 % to 17 %), and after they were carried out (for soot measurements, average deviation was −1.0 % and the range −14 % to 8 %; for nigrosin measurements, the average deviation was 0.5 % and the range −12 % to 15 %). The deviations are in most of the cases explained by the type of filter material employed by the instruments, the total particle load on the filter, and the flow calibration. The results of this intercomparison activity show that relatively small unit-to-unit variability of AE33-based particle light absorbing measurements is possible with well-maintained instruments. It is crucial to follow the guidelines for maintenance activities and the use of the proper filter tape in the AE33 to ensure high quality and comparable black carbon (BC) measurements among international observational networks.
Ključne besede:black carbon, aerosol, absorption, filter absorption photometer, aethaloemter
Leto izida:2021
Št. strani:str. 3195-3216
Številčenje:Vol. 14, iss. 4
PID:20.500.12556/RUNG-6517 Novo okno
COBISS.SI-ID:61521411 Novo okno
UDK:504
ISSN pri članku:1867-1381
DOI:10.5194/amt-14-3195-2021 Novo okno
NUK URN:URN:SI:UNG:REP:REHN0IXX
Datum objave v RUNG:03.05.2021
Število ogledov:2789
Število prenosov:0
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Atmospheric measurement techniques
Skrajšan naslov:Atmos. meas. tech.
Založnik:Copernicus Publications
ISSN:1867-1381
COBISS.SI-ID:517910809 Novo okno

Nazaj