Repository of University of Nova Gorica

Search the repository
A+ | A- | Help | SLO | ENG

Query: search in
search in
search in
search in
* old and bologna study programme

Options:
  Reset


1 - 2 / 2
First pagePrevious page1Next pageLast page
1.
Performance analysis of high-spectral-resolution lidar with/without laser seeding technique for measuring aerosol optical properties
Fengjia Gao, Fei Gao, Gaipan Li, Fan Yang, Li Wang, Song Yuehui, Dengxin Hua, Samo Stanič, 2024, original scientific article

Abstract: High-spectral-resolution lidar (HSRL) is a powerful tool for aerosol measurements. With/without laser seeding technique in the transmitted laser, the HSRL can be distinguished as the single-longitudinal-mode (SLM) HSRL or the multi-longitudinal-mode (MLM) HSRL, and the Mach-Zehnder interferometer (MZI) with periodic transmittance function can be used as the spectral discriminator in both the SLM HSRL and MLM HSRL. To in-depth knowledge of the respective advantages of the SLM HSRL and MLM HSRL for measuring aerosol optical properties, the working principle, optimal parameter setting, and detection performance of the SLM HSRL and MLM HSRL are analyzed and discussed in detail, respectively. The working principle of the SLM HSRL and MLM HSRL indicate that the effective transmittance of MZI is the important parameter of data retrieval, the main source of retrieval uncertainties, and the key factor of MZI optical path difference (OPD) settings. To ensure that the MZI can achieve the preferable separation for aerosol Mie scattering signals and molecular Rayleigh scattering signals, the optimal OPDs of MZI are set at 165 mm and 1000 mm in the SLM HSRL and MLM HSRL from the aspects of the effective transmittance of MZI and the spectral discrimination ratio (SDR). Besides, to analyze the influence of frequency difference and divergence angle for the detection performance of HSRL, the effective transmittance of MZI and SDR are simulated and the results show that the MLM HSRL has higher requirements for the environmental parameters and the echo beam collimation than the SLM HSRL. Moreover, the HSRLs with SLM and MLM transmitted lasers are constructed in Xi'an for measuring aerosol optical properties. The preliminary measurement results show that the range square corrected signal (RSCS) of Rayleigh channel is smaller than that of Mie channel in both the SLM HSRL and MLM HSRL, while the difference between RSCS of Rayleigh channel and RSCS of Mie channel in the SLM HSRL is larger than that in the MLM HSRL, and the detection range of the SLM HSRL is lower than that of the MLM HSRL.
Keywords: aerosol optical properties, high-spectral-resolution lidar, single-longitudinal-mode, multi-longitudinal-mode, spectral discrimination ratio
Published in RUNG: 28.02.2024; Views: 1489; Downloads: 3
URL Link to file
This document has many files! More...

2.
Investigation of the effective transmittance of Mach-Zehnder interferometer in the multi-longitudinal-mode high-spectral-resolution lidar
Fei Gao, Fengjia Gao, Xiao Yang, Gaipan Li, Li Wang, Meng Wang, Dengxin Hua, Griša Močnik, Samo Stanič, 2022, original scientific article

Abstract: Effective transmittance is an important parameter of Mach-Zehnder interferometer in the retrieval of aerosol optical properties using the multi-longitudinal-mode high-spectral-resolution lidar, which is a function of the complex degree of coherence. In this paper, we retrieve the parameter of the complex degree of coherence for the multi-longitudinal-mode laser from the theoretical analysis, optical simulation and experimental measurements, which are 0.726, 0.678 and 0.453 using the Mach-Zehnder interferometer with the optimal optical path difference of two times of laser optical cavity length (∼1000 mm) and under the light illumination of the high power Nd:YAG laser with the mode number of 101 and mode interval of 300 MHz under the condition of laser linewidth of 1 cm−1 (30 GHz). The preliminary measurement results of aerosol optical properties using the constructing multi-longitudinal-mode high-spectral-resolution lidar show that the difference of the complex degree of coherence retrieved from the presented methods results in the relative error of 40% in the aerosol backscattering coefficient with thin cloud layer and 90% with the presence of dense aerosol layer.
Keywords: effective transmittance, Mach-Zehnder interferometer, Multi-logitudinal-mode laser, High-spectral-resolution lidar
Published in RUNG: 20.09.2022; Views: 2427; Downloads: 0
This document has many files! More...

Search done in 0.01 sec.
Back to top