1.
“LESSONS LEARNED” (PARTIAL TEST DEPLOYMENTS REPORT)
Tomislav Brajnović,, Peter Purg, Daniela Brasil, Alessandro Bordina, Miljana Babić, 2014, other monographs and other completed works

Abstract: The report consist of individual test-run reports by participating teachers and consortium-level observers that gathered qualitative and quantitative data through short interviews, surveys and QA questionnaires mostly with students, but also among themselves. A joint evaluation is delivered and a “lessons learned” compendium published, offered digitally through the project’s dissemination system (mostly newsletter and website-promotion), and spread locally through the teaching communities – also partly entering the professional article as “experience report” (see next deliverable). These reports and the “lessons learned” were discussed and confirmed in the below structure at the September 2013 meeting, organised by P4. Notably, a total of three sceintific or porfessional articles were (to be) published (as separate deliverables) refereing to the lessons learned in this project, refering to the summative experience of the project.
Found in: ključnih besedah
Summary of found: ...Curriculum, module, course, study programme, degree, international, comparison, study,...
Keywords: Curriculum, module, course, study programme, degree, international, comparison, study, national, studio, MA
Published: 05.07.2016; Views: 4176; Downloads: 211
URL Fulltext (0,00 KB)
This document has many files! More...

2.
Development of prototype of electronic speckle interferometry based spirometer
SANKARARAMAN SANKARANARAYANA IYER, RAJ VIMAL, SREEJYOTHI S, KUMAR SUNIL, KUMAR ARUN, Swapna Mohanachandran Nair Sindhu, 2021, original scientific article

Abstract: The paper reports the design, construction, and calibration of the prototype of a spirometer based on electronic speckle interferometry (ESPI). The conventional ESPI setup is modified by incorporating a DNM (Diaphragm-Nozzle-Mouthpiece) module comprising a metallic diaphragm, regulated airflow channel, and a mouthpiece. The exhaled air after a deep breathe is channelled to the DNM module where the diaphragm gets deformed. From the circular fringe pattern obtained by subtracting the speckled images before and after deformation of the metallic diaphragm, the radius of curvature (R) due to deformation is calculated using the principle of Newton’s rings. The value of R and peak expiratory flow rate (PEFR) from the standard spirometer reading are correlated. From the 640 observations spread over the range 100 - 500 L/min in the standard spirometer, an empirical relation is set in terms of R from the scatter plot. The ESPI spirometer (ESPIS) is validated by determining the value of R corresponding to a particular PEFR from the empirical relation and also from the standard spirometer. The PEFR calculated from ESPIS matches well with the standard spirometer reading, which suggests that the system designed and constructed can be used for biomedical applications for assessing lungs’ efficiency.
Found in: ključnih besedah
Summary of found: ...is modified by incorporating a DNM (Diaphragm-Nozzle-Mouthpiece) module comprising a metallic diaphragm, regulated airflow channel,...
Keywords: Speckle, Spirometer, DNM module, ESPIS, Peak expiratory flow rate
Published: 28.06.2022; Views: 490; Downloads: 0
.pdf Fulltext (2,38 MB)