Title:Nadgradnja sistema daljinskega ogrevanja s trajnostno energijo : magistrsko delo
Authors:ID Jakin, Tomaž (Author)
ID Gjerkeš, Henrik (Mentor) More about this mentor... New window
Files:URL http://repozitorij.ung.si/IzpisGradiva.php?id=5051
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:PTF - Faculty of Engineering and Management
Abstract:V magistrski nalogi smo na podlagi podrobne analize obstoječega sistema daljinskega ogrevanja predlagali variantne nadgradnje, ki bodo znižale ceno ogrevanja in povečale energetsko učinkovitost skladno s strategijo EU in Slovenije na področju trajnostnega ogrevanja stavb. Izgube sistema smo po znižanju temperature vtoka glavnega razvoda iz 75°C na 65°C znižali z 21,68 % na 16,28 %. V analizi trajnostnih in okoljskih vidikov zamenjave obstoječega energenta smo izvedli primerjavo različnih energentov upoštevajoč izkoristek posameznega sistema. Naredili smo primerjavo med zemeljskim plinom, sekanci, peleti in toplotna črpalka (TČ). Podrobneje smo analizirali TČ za objekt 14 in ugotovili da je TČ je ekonomsko in trajnostno v analiziranem primeru najučinkovitejša rešitev. V prvi fazi ekonomske analize smo naredili izračun denarnega toka za sanacijo izolacije glavnega razvoda. Ocena znižanja obratovalnih stroškov temelji na znižanju toplotnih izgub vročevoda s 16,28 % na 4,71 %. Investicija se povrne v 10 letih. Ocena finančnih kazalnikov investicije v TČ brez sanacije izolacije glavnega razvoda za vse objekte upošteva prihranke zgolj zaradi nižje cene toplote iz TČ v primerjavi s plinskim kotlom. Investicija se povrne v 8 letih. Pokazali smo, da ima celovit pristop s toplotno sanacijo vročevoda ob hkratni zamenjavi plinskih kotlov s
Keywords:sistemi daljinskega ogrevanja, trajnostna energija, toplotne črpalke, zemeljski plin, sončne elektrarne, magistrske naloge
Place of publishing:Nova Gorica
Place of performance:Nova Gorica
Publisher:T. Jakin
Year of publishing:2021
Year of performance:2021
Number of pages:XII, 58 str.
PID:20.500.12556/RUNG-5051-29285a34-cb23-7ff2-80a1-84966a9dc4d9 New window
COBISS.SI-ID:64499203 New window
UDC:620.92/.98
NUK URN:URN:SI:UNG:REP:NRTOO4FN
Publication date in RUNG:25.05.2021
Views:3128
Downloads:108
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:District heating system up grade With sustainable energy : master thesis
Abstract:In the master's thesis, based on a detailed analysis of the existing district heating system, the master's thesis suggested variants of upgrades that will lower the price of heating and increase energy efficiency in accordance Wirth the EU and Slovenia's strategy in the field of sustainable heating of buildings We have reduced system losses from 21.68 % to 16.28 % after decreasing the flow temperature of the main distribution from 75 °C to 65 °C. In the analysis of the sustainable and environmental aspects of the replacement of the existing energy source, a comparison of different energy products was made taking into account the efficiency of each system. We made a comparison between natural gas, wood chips, pellets, and heat pump (HP). We analyzed the heat pump for object 14 in detail. The heat pump is the most economically sustainable solution. In the first phase of the economic analysis, we made a calculation of the cash flow for the restoration of the isolation of the main pipeline. Revenues or reduced costs are based on a reduction in losses from the existing 16.28 % in the calculation ratio of 4.71 % and are valued at the price of natural gas. An investment refunded within 10 years. An investment in the heat pump without the repair of the main pipeline for all objects is based on a comparison of the use of natural gas and electricity for the use of the heat pump and is valued on the price of natural gas. An investment refundable within 8 years. The correct legislative and sustainable approach to the rehabilitation of the conditions is the investment in the heat pump and the rehabilitation of the isolation of the main pipeline. An investment refunded in 11 years.
Keywords:District heating system, sustainable energy, heat pumps, natural gas